Installation of Indoor Unit
ELECTRICAL WIRING
HOW TO CONNECT WIRING TO THE TERMINALS A.For solid core wiring (or
(1)Cut the wire and with a wire cutter or
(2)Using a screwdriver ,remove the terminal screw(s) on the terminal board. (3)Using pliers,bend the solid wire to form a loop suitable for the terminal screw.
B.For strand wiring
(1)Cut the wire and with a wire cutter or
(2)Using a screwdriver ,remove the terminal screw(s) on the terminal board.
Fig. 14
Strip 15/16"(25mm)
A. Solid wire |
| B. Strand wire |
| Loop | 15/16"(25mm) |
|
| |
Insulation |
| Strip |
|
|
Round terminal
| Screw with |
| special washer |
| Round |
| terminal |
| Terminal |
Wire | board |
| |
| Wire |
Screw with special washer
Round terminal
HOW TO FIXED CONNECTION CORD AND POWER CABLE AT THE CORD CLAMP
After passing the connection cord and power cable through the insulation tube, fasten it with the cord clamp, as shown in Fig.15