Installation procedures

Installation of indoor unit

Selection of installation place

Place where it is easy to route drainage pipe and outdoor piping. Place away from heat source and with less direct sunlight.

Place where cool and warm air could be delivered evenly to every corner of the room. Place near power supply socket. Leave enough space around the unit (refer to installation drawings).

Fixing of the unit

1.Position of the wall hole

Wall hole should be decided according to installtion place and piping direction. (refer to installation drawings)

2.Making a wall hole

Drill a hole of 70mm dia. with a little slope towards outside. Install piping hole cover and seal it with putty after installation.

INDOOR

wall hole

70mm

OUTDOOR UNIT

wall thinkness

( Cross section of wall hole )

Fixing of indoor unit

To prevent it from fall off, please fix the unit with fall-prevention fitting at wall and L-shaped metal at floor.

Self-tapping screw

all-prevention fitting metal (accessory)

Wood screw

Please install the whole unit horizontally, with a slop of 1 degree at front and rear, left and right.

L-shaped metal (accessory)