Haier AU342XHERA Wiring work, Correct Pressing, Wrong Pressing, Terminal, block, Pressing Clamps

Models: AU342XHERA

1 20
Download 20 pages 10.67 Kb
Page 15
Image 15
 Wiring work
Wiring Method for Ring Terminal Block

Correct Pressing Wiring work

1.Electric wiring Note:

Wrong Pressing The air conditioner must use special circuit , and wiring by the qualified electrician according to the wiring rules specified in national standard.

Terminal The grounding wire and the neutral wire shall be strictly separated. Connect the neutral wire with grounding wire is incorrect.

block The electric leakage breaker must be installed.

Pressing All the electric wire must be copper wire.When wiring,there shall keep a proper distance between the power line and communication wire to avoid twist together. Otherwise,signal disturbance will occur,and the air conditioner can not operate normally. Power supply: 1PH, 220-230V~, 50Hz.

Manual background The wiring method of power line is Y connection. If the power line is damaged, in order to avoid risk of electric shock, it must be replaced by the manufacturer or its repair center or other similar qualified person.The connecting cable must be shielded.

Manual background Fuse: T3.15A 250VAC T25A 250VAC (Please check with the outdoor unit wiring diagram.)

Manual background Please check the circuit diagram about the fuse replaced.

2. Wiring method Wiring method of orbicular terminals

For the connection wire with orbicular terminals, its wiring method is as shown in the right figure: remove the connecting screw, put the screw through the ring on the

end of the wire, then connect to the terminal block and fasten screw. Wiring method of straight terminals

For the connection wire without orbicular terminals, its wiring method is: loosen

the connection screw, and insert the end of the connection wire completely into the Terminal block, then fasten the screw. Slightly pull the wire outwards to confirm it is firmly held.

Correct Pressing

Wrong Pressing

 

Terminal

 

block

Pressing

Clamps

Crimp connection method for wires without terminals

Connect the wire with same diameter to the two sides of the terminal

Do not connect the

Do not connect the

wire with same diameter

wire with different

to the same side

diameters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 