Routine maintenance

Routine maintenance

Fault clearance

Warning

To avoid electric shock or personal injury, be sure to disconnect the freezer from power supply before carrying out any repair or maintenance.

Make sure that no drug or suspended particles around the freezer will be breathed in at the time of maintenance; otherwise they may result in health hazard.

Cleaning of the freezer

Equipment scrapping Clean the freezer once a month. Regular cleaning makes the freezer always brand-new.

Manual background Wipe off a little dust on the shell, inner compartments and all accessories of the freezer with a dry cloth. If the freezer is very dirty, remove the dirt with a clean cloth and neutral detergent, then wipe off the residual detergent with a wet cloth, and finally wipe the freezer with a dry cloth. (Undiluted detergent may damage plastic parts. Please refer to the detergent instructions for the dilution method.)

Manual background Never pour water onto the shell or into the preservation compartment of freezer; otherwise the insulation layer may be damaged, resulting in faults.

Manual background The compressor and other mechanical parts are fully enclosed and require no lubrication. Manual background Remove the frost or ice on the inner wall once a month.

Removal of frost on the inner wall

Frost usually forms on internal shelve, which may cause clearance between the cabinet body and door seal and thus result in poor refrigerating effect. You may use the ice scraper provided along with the freezer for defrosting. The following procedure is the method of defrosting through emptying the freezer.

Note: Do not use any tool with sharp edges or corners such as knife or screwdriver for defrosting.

1.Take out all articles stored in the freezer and put them in another freezer or in a container with freezing liquid carbon dioxide.

2.Turn off the power switch.

3.Open outer doors and leave them open for a period of time for defrosting.

4.Wipe off water at the bottom of cabinet body with a dry cloth.

5.After cleaning the cabinet body, turn on the freezer again.

6.Put back the articles in the sufficiently cooled freezer.

Or you may use the “Defrost” key to defrost: after unlocking the keyboard, press and hold the “Defrost” key for 5s, the compressor will stop running. This key doesn’t have automatic return function. Therefore it is necessary to press and hold it for 5s again after defrosting ends, and the compressor will resume normal running.

Battery maintenance

Manual background When the low-temperature freezer keeps working continuously, please test the battery charge level every 15 days (please refer to the section of alarm test function on Page 12 for the test method). In case of low battery charge level, make sure that the battery switch is on and the battery is charged. When the battery has been charged for consecutive 7 days, please retest the battery charge level. In normal conditions, the battery charge should be full. If low battery charge level remains, it is recommended to replace the rechargeable battery.

Manual background The battery with power-down alarm function is a consumable item with 3-year service life. If the battery has been used for more than 3 years, it may not act at the time of alarm. It is recommended to replace the battery earlier. Please contact a Haier after-sales service technician for the battery replacement.

If the freezer goes wrong, please check the following possible fault points before asking for repair:

Failure to start

Manual background Is the connection of power supply normal? Is the main power switch on?

Manual background Is supply voltage too low?

Manual background Were many articles put in the freezer at a time? Poor cooling

Manual background Is ambient temperature too high?

Manual background Are the doors closed tightly? (The frost between the cabinet body and the door seal may reduce the sealing performance of doors)

Manual background Is the temperature setting correct?

Manual background Is the freezer away from direct sunlight?

Manual background Is the freezer close to a heat source?

Manual background Are the rubber hole cover and heat-insulating materials of test through-hole placed correctly?

Manual background Were many uncooled items put in the freezer in past several hours? (In this case, the problem is temporary. You may raise the set temperature and then gradually reduce it after the freezer starts and stops normally in a short time.)

Noise

Manual background Is the freezer installed on solid ground?

Manual background Is the freezer’s shell contact with any object?

Manual background Has the freezer been leveled by adjusting its legs?

Manual background Is the freezer in low-temperature running state?

If the freezer’s internal temperature is relatively high due to many items in it, sometime it make noises. The noise will lower with the reduction of temperature in the preservation compartment.

Manual background Please check whether the noise is from the compressor (the compressor noise of low-temperature equipment is louder than that of household appliances)