ʄPress the TEMP/TIME up arrow button to raise the temperature. Each time you press or hold the TEMP/TIME up arrow button, the temperature will go up 1ºF until it reaches 86°F (30°C).

NOTE: After 5 seconds, the display will show the current room temperature.

ʄPress the TEMP/TIME down arrow button to lower the temperature. Each time you press or hold the TEMP/TIME down arrow button, the temperature will go down 1ºF until it reaches 61°F (16°C).

NOTE: After 5 seconds, the display will show the current room temperature.

Timer Delay

To set the Timer for a 1-hour to 24-hour delay until the air conditioner turns off (the air conditioner must be On):

3UHVV7,0(57LPHU2))LQGLFDWRUOLJKWZLOOÀDVK'LVSOD\ZLOO show remaining hours before the air conditioner will turn off.

2.Press the TEMP/TIME up or down arrow button to change the delay time from 1 hour to 24 hours.

3.After 5 seconds, Timer OFF indicator light will remain on. Display will show the current room temperature.

To set the Timer to turn on the air conditioner, keeping previous settings:

1.Turn off the air conditioner.

3UHVV7,0(57LPHU2QLQGLFDWRUOLJKWZLOOÀDVK'LVSOD\ZLOO show remaining hours before the air conditioner will turn on.

3.Press the TEMP/TIME up or down arrow button to change the delay time from 1 hour to 24 hours.

4.Timer On indicator light will remain on.

To set the Timer to turn on the air conditioner, changing the previous settings:

1.Turn on the air conditioner.

2.Adjust the mode to Fan, Cool, Energy Saver or Dehum.

3.For Fan, Cool or Energy Saver mode, adjust the fan speed to High, Med or Low.

4.Adjust the temperature between 61ºF and 86ºF (16ºC and 30ºC).

NOTE: In Fan mode, the temperature cannot be set.

3UHVV7,0(57LPHU2QLQGLFDWRUOLJKWZLOOÀDVK'LVSOD\ZLOO show remaining hours before the air conditioner will turn on.

6.Press the TEMP/TIME up or down arrow button to change the delay time from 1 hour to 24 hours.

7.Timer On indicator light will remain on.

To clear Timer delay program:

NOTE: Air conditioner can be either on or off.

1.Press TEMP/TIME once after it has been programmed. Display will show remaining time.

2.While the display is showing the remaining time, press TIMER untill Timer indicator light turns off.

To see or change the remaining time (in hours):

Timer Off :

1.Press TEMP/TIME once after it has been programmed.

Display on the air conditioner control panel will show remaining time.

2.While the display is showing the remaining time, press

the TEMP/TIME up or down arrow button to increase or decrease the time.

3.After 5 seconds, the display on the air conditioner control panel will show the current room temperature.

Timer On :

1.Display on the air conditioner control panel will show remaining time.

2.While the display is showing the remaining time, press the TEMP/TIME up or down arrow button to increase or decrease the time.

10

Page 10
Image 10
Haier ESA424K manual Temperature, Timer Delay, To clear Timer delay program, To see or change the remaining time in hours

ESA424K, ESA424K-L specifications

Haier, a renowned global leader in home appliances, has made waves in the air conditioning industry with its innovative products. Among their impressive lineup are the Haier ESA415M, ESA424K, and ESA418M window air conditioners. These models stand out not only for their aesthetic appeal but also for their superior technologies and features designed to enhance user comfort and energy efficiency.

Starting with the Haier ESA415M, this model is tailored for smaller rooms, making it an excellent choice for bedrooms or home offices. One of its main features is the 15000 BTU cooling capacity, which allows it to quickly cool spaces up to 700 square feet. This air conditioner is equipped with a programmable thermostat that allows users to maintain their desired temperature with ease. Additionally, the ESA415M boasts three cooling speeds and three fan speeds, providing a range of options for personalized climate control. Its energy efficiency ratio (EER) ensures that it operates economically, helping to keep utility bills manageable.

Next, we have the Haier ESA424K, a versatile model ideal for larger spaces. With a powerful 24000 BTU rating, this unit is designed for rooms up to 1000 square feet. The ESA424K features a digital display and remote control functionality, allowing users to adjust settings from anywhere in the room. Its integrated air purification technology not only cools the air but also helps to filter out dust and allergens, ensuring a healthier living environment. Furthermore, this model includes a dehumidification mode, which effectively reduces moisture levels, enhancing overall comfort during humid months.

Lastly, the Haier ESA418M combines style and efficiency, making it a perfect fit for modern homes. With a cooling capacity of 18000 BTU, it effortlessly cools spaces up to 800 square feet. This model also emphasizes energy efficiency, featuring the ENERGY STAR certification. One of its standout characteristics is the quiet operation, making it suitable for use in bedrooms and study areas. The ESA418M offers a range of convenient features including a 24-hour timer, allowing users to automate the air conditioning schedule to fit their lifestyle.

In conclusion, the Haier ESA415M, ESA424K, and ESA418M represent the brand’s commitment to providing high-quality air conditioning solutions. Each model is equipped with advanced features and technologies that cater to various cooling needs, ensuring comfort while being mindful of energy consumption. Whether for a small bedroom, a large living area, or a home office, Haier has a window air conditioner to meet every requirement.