2.Temperature Setting

With the machine powered on (with no any digits flashing on the display), press Model or Volume

Dimensions

(Fig.1)

button to enter temperature setting status with the temperature digits rapidly flashing. Temperature can be changed between 35 - 75 Weight with an increment 1 22kg . In real-time heating mode, you can directly press 25kg or 29kg button to adjust temperature setting value. In

medium warm status, machine defaulted highest temperature is 40 100L and can't be adjusted. If actual water temperature is lower than setting value and the machine is in medium warm mode, you need to change operation mode to real-time heating mode, and then the machine can heat water to the set temperature.

3.Clock Calibration

Clock goes in 24-hour and 60-min system in a second flashing way. Example: calibrate the clock to 11:29

After powering on, in real-time heating and night power modes, you can press Set button

Front View

a1

1b

C1

Bottom View

I A B

1d

I: Drain

to enter clock calibration status with hour digits flashing. Press 34kg or Attentions in installation button to set 11.

Press Set button again and minute digits flash. Press Manual background or Manual background button to set 29. You can press Set button to confirm current setting, or wait 6 s after which the system will automatically confirms and quits setting status (as shown in Fig. 7, machine is in real-time heat / warm mode).

HEATING

ACTUAL

Fig.7

Model

 

Volume

Net

 

Weight

FCD-JTHMG50-

E

50L

22kg

 

 

 

 

FCD-JTHMG60-

E

60L

25kg

 

 

 

 

FCD-JTHMG80-

E

80L

29kg

 

 

 

 

FCD-JTHMG100-

E

100L

34kg

 

 

 

 

a1

b1

c1

671mm

 

 

 

442mm

100mm

765mm

442mm

100mm

 

 

 

 

 

 

876mm

479mm

100mm

1052mm

 

 

 

479mm

100mm

 

 

 

 

d1

410mm

410mm

450mm

450mm

Fig.6

4. Power Level Selection

With the machine powered on, press Power button to directly go to power level selection status. You can select a power level 850 W, 1300 W or 2150 W. If 850 W is selected, 850 W digits are lighted and only the upper heating element works. If 1300 W is selected, 1300 W digits are lighted and only the lower heating element works. If 2150 W is selected, 2150 W digits are lighted and both the upper and lower heating elements work. In Delay mode, machine defaulted heating power is 2150 W and can't be adjusted. Fig. 8 shows a heating power level 2150 W, the present clock time 12:10, and the real-time heating mode.

5.Real-time Heat / Warm Setting

With machine powered on, as described in Item 10, press Mode button to enter Real-time Heat / Warm mode with real-time heat indication lighted on. According to settings, machine will automatically starts to heat or keep warm. The machine has a thermostat function, by which, the machine goes into warm keeping status when it reaches the temperature setting value. In warm keeping status, machine automatically starts heating when actual water temperature is 5Manual background (for setting value lower than 55Manual background ) or 10Manual background (for setting value equal to or above 55Manual background ) lower than the setting value, until reaching setting temperature again. It repeats in this way.

Example: Fig. 9 shows real-time heat / warm status with heating power 1300W and temperature setting 75Manual background .

HEATING

SET

HEATING

ACTUAL

Fig.8

Fig.9

6.Medium Warm Setting

With machine powered on, as described in Item 10, press Mode button until it enters Medium Warm operation mode (with Medium Warm indication on the display).

Remarks:the permitted error limit of above parameters is Manual background 10%.

Attentions in installation

Manual background During installation, adequate space must be reserved for future maintenance and repair. If the water heater is installed within decoration boards, the right board shall be removable to facilitate removing the plastic cover during maintenance.

Manual background City water inlet pressure shall not be less than 0.05 Mpa.

Manual background Electric water heater shall be installed indoors with ambient temperature above 0Manual background . The pipes shall be collectively laid. Hot water outlet shall not be too far from use points. In case farer than 8 m, hot water pipe shall have a thermal insulation to minimize heat loss.

Manual background The mounting wall shall be firm and reliable to support twice the weight of water heater full of water. Non-load bearing walls or air brick walls must have corresponding protective measures like additional support, wall-through screws or back boards.

Manual background Electric water heater shall be located in a place easy for use, maintenance and with a floor drainer. In case the tank or pipes leak, nearby or lower facilities shall not be damaged. The installation location shall avoid being above toilet bowl, bathtub, washbasin or doorframe, where will cause a suppressed or unsafe feeling to users.

Manual background Power socket for water heater shall be in a dry place free of water splash to avoid nonnormal work of the water heater. (splash-proof box is preferred)

Manual background Do not confuse inlet and outlet water pipes. Safety valve shall be installed at designated position with no random modification. The safety valve pressure relief vent shall keep open to the air. Do not block it.

Manual background To ensure safety, water heater shall use a separate socket (not multi-purpose socket) and be reliably grounded. Socket quality shall comply with local standard. Check with a neo-electroscope the line and neutral are not wrongly connected. Only after confirming the tank is full of water, no water leakage at various connections and power supply meets requirements, power can be turned on to start heating.

Page 7
Image 7
Haier FCD-HTHMG50-III(E), FCD-HTHMG60-III(E), FCD-HTHMG80-III(E), FCD-HTHMG100-III(E) Dimensions, Operation Instructions