![Dimensions](/images/new-backgrounds/32742/3274213x1.webp)
Operation Instructions
2.Temperature Setting
With the machine powered on (with no any digits flashing on the display), press or
Dimensions
(Fig.1)
button to enter temperature setting status with the temperature digits rapidly flashing. Temperature can be changed between 35 - 75 with an increment 1
. In
or
button to adjust temperature setting value. In
medium warm status, machine defaulted highest temperature is 40 and can't be adjusted. If actual water temperature is lower than setting value and the machine is in medium warm mode, you need to change operation mode to
3.Clock Calibration
Clock goes in
After powering on, in
Front View
a1 |
1b
C1 |
Bottom View
I A B
1d
I: Drain
to enter clock calibration status with hour digits flashing. Press or
button to set 11.
Press Set button again and minute digits flash. Press or
button to set 29. You can press Set button to confirm current setting, or wait 6 s after which the system will automatically confirms and quits setting status (as shown in Fig. 7, machine is in
HEATING
ACTUAL |
Fig.7 |
Model |
| Volume | Net |
| Weight | ||
E | 50L | 22kg | |
|
|
|
|
E | 60L | 25kg | |
|
|
|
|
E | 80L | 29kg | |
|
|
|
|
E | 100L | 34kg | |
|
|
|
|
a1 | b1 | c1 | |
671mm |
|
|
|
442mm | 100mm | ||
765mm | 442mm | 100mm |
|
| |||
|
|
|
|
876mm | 479mm | 100mm | |
1052mm |
|
|
|
479mm | 100mm | ||
|
|
|
|
d1
410mm
410mm
450mm
450mm
Fig.6 |
4. Power Level Selection
With the machine powered on, press Power button to directly go to power level selection status. You can select a power level 850 W, 1300 W or 2150 W. If 850 W is selected, 850 W digits are lighted and only the upper heating element works. If 1300 W is selected, 1300 W digits are lighted and only the lower heating element works. If 2150 W is selected, 2150 W digits are lighted and both the upper and lower heating elements work. In Delay mode, machine defaulted heating power is 2150 W and can't be adjusted. Fig. 8 shows a heating power level 2150 W, the present clock time 12:10, and the
5.
With machine powered on, as described in Item 10, press Mode button to enter (for setting value lower than 55
) or 10
(for setting value equal to or above 55
) lower than the setting value, until reaching setting temperature again. It repeats in this way.
Example: Fig. 9 shows .
HEATING | SET | HEATING |
ACTUAL
Fig.8 | Fig.9 |
6.Medium Warm Setting
With machine powered on, as described in Item 10, press Mode button until it enters Medium Warm operation mode (with Medium Warm indication on the display).
Remarks:the permitted error limit of above parameters is 10%.
Attentions in installation
During installation, adequate space must be reserved for future maintenance and repair. If the water heater is installed within decoration boards, the right board shall be removable to facilitate removing the plastic cover during maintenance.
City water inlet pressure shall not be less than 0.05 Mpa.
Electric water heater shall be installed indoors with ambient temperature above 0
. The pipes shall be collectively laid. Hot water outlet shall not be too far from use points. In case farer than 8 m, hot water pipe shall have a thermal insulation to minimize heat loss.
The mounting wall shall be firm and reliable to support twice the weight of water heater full of water.
Electric water heater shall be located in a place easy for use, maintenance and with a floor drainer. In case the tank or pipes leak, nearby or lower facilities shall not be damaged. The installation location shall avoid being above toilet bowl, bathtub, washbasin or doorframe, where will cause a suppressed or unsafe feeling to users.
Power socket for water heater shall be in a dry place free of water splash to avoid nonnormal work of the water heater.
Do not confuse inlet and outlet water pipes. Safety valve shall be installed at designated position with no random modification. The safety valve pressure relief vent shall keep open to the air. Do not block it.
To ensure safety, water heater shall use a separate socket (not