Haier HC18-60A1VAR/S Operation, Miscellaneous, Replacement Parts, Troubleshooting Guide

Models: HC18-60A1VAR/S HC18-60D1VAR HC18-60C1VAR

1 17
Download 17 pages 43.73 Kb
Page 14
Image 14

8.OPERATION

Most single phase units are operated without start relay or start capacitor. Such systems should be off for a minimum of 5 minutes before restarting to allow equalization of pressures. The thermostat should not be moved to cycle unit without waiting 5 minutes. To do so may cause the compressor to stop on an automatic open overload device or blow a fuse. Poor electrical service can cause nuisance tripping in overloads or blow fuses.

The compressor has an internal overload protector. Under some conditions, it can take up to 2 hours for this overload to reset. Make sure overload has had time to reset before condemning the compressor.

9.MISCELLANEOUS

9.1.Replacement Parts

Contact your local distributor for a complete parts list.

9.2.Troubleshooting Guide

Refer to the troubleshooting guide (Table 10) included in this manual.

9.3.Wiring Diagram

Refer to the appropriate wiring diagram included in this manual.(P14)

Table 10:Troubleshooting Guide

!WARNING - Disconnect all electrical power to the unit before servicing. Disconnect power to both the indoor and outdoor units. NOTE: There may be more than one electrical disconnect switch. Failure to shut off power can cause electrical shock resulting in personal injury or death.

12

Page 14
Image 14
Haier HC18-60A1VAR/S, HC18-60C1VAR Operation, Miscellaneous, Replacement Parts, Troubleshooting Guide, Wiring Diagram