Haier HC18-60C1VAR, HC18-60A1VAR/S operation manual System Cooling Capacity, Model HC18-60D1VAR

Models: HC18-60A1VAR/S HC18-60D1VAR HC18-60C1VAR

1 17
Download 17 pages 43.73 Kb
Page 6
Image 6

Table 4:System Cooling Capacity

Outdoor Unit

With This Indoor Air handler

 

 

 

 

Model Number

Air Handler

Compressor

Cooling Capacity (Btu/h)

SEER

Rated

 

 

 

 

 

 

 

CFM(Outdoor)

 

 

brand

Sensible

Total

 

HC18C1VAR

HB2400VC1M20

Bristol

14820

19000

 

12

1950

HC24C1VAR

HB2400VC1M20

Bristol

18720

24000

 

12

1950

HC30C1VAR

HB3600VA1M20

Bristol

23400

30000

 

12

1950

HC36C1VAR

HB3600VC1M25

Bristol

25920

36000

 

12

2700

HC42C1VAR

HB4800VA1M25

Bristol

30240

42000

 

12

2900

HC48C1VAR

HB4800VA1M25

Bristol

34560

48000

 

12

2900

HC60C1VAR

HB6000VC1M25

Bristol

41800

58000

 

12

2900

The dimensions for the condensing unit are illustrated in Figure 1. Physical and electrical specifications are provided in Table 5 for 13 SEER systems respectively.

Table 5: Model:HC18-60D1VAR

MODEL:

 

HC18D1VAR

HC24D1VAR

HC30D1VAR

HC36D1VAR

HC42D1VAR

HC48D1VAR

HC60D1VAR

Unit Supply Voltage

 

 

 

208/230-1-60

 

 

 

Normal Voltage Range

 

 

 

197 - 253

 

 

 

Compressor Brand

 

 

 

Bristol

 

 

 

Minimum Circuit Amps

8.6

11.6

12.4

15.9

17.7

21.8

33.3

Max Fuse or Max CKT. BKR.

 

 

 

 

 

 

 

(HACR per NEC )

15

20

20

25

30

35

55

 

Rated Load Amps

6.2

8.6

9.2

11.7

13.0

15.8

25.0

Compressor

Locked Running

 

 

 

 

 

 

 

 

Amps

41

60

60

73

85

90

150

 

 

 

 

 

 

 

 

 

 

Full Load Amps

0.86

0.86

0.86

1.3

1.43

2.0

2.0

 

 

 

 

 

 

 

 

 

Fan Motor

Rated HP

1/8

1/6

1/6

1/4

1/3

1/3

1/3

 

Nominal RPM

1000

840

840

850

1075

960

880

Liquid Line OD - In (mm)

3/8"[9.52]

3/8"[9.52]

3/8"[9.52]

3/8"[9.52]

3/8" [9.52]

3/8"[9.52]

3/8"[9.52]

 

 

 

 

 

 

 

 

 

Vapor Line OD - In (mm)

3/4"[19.05]

3/4"[19.05]

3/4"[19.05]

7/8"[22.2]

7/8"[22.2]

7/8"[22.2]

7/8"[22.2]

 

 

 

 

 

 

 

 

 

R-22 Charge -Oz (g)

93.64[2650]

102.47[2900]

121.91[3450]

134.28[3800]

148.41[4200]

178.45[5050]

196.11[5550]

 

 

 

 

 

 

 

 

 

Net Dimensions - In (mm)

23*23*31 1/2

30 1/4*30 1/4*27 3/4

30 1/4*30 1/4*31 1/2

30 1/4*30 1/4*31 1/2

30 1/4*30 1/4*35 1/2

30 1/4*30 1/4*31 1/2

30 1/4*30 1/4*35 1/2

W*D*H

 

[585* 585*805]

[770* 770*705]

[770* 770*805]

[770 *770*805]

[770 *770*905]

[770 *770*805]

[ 770 *770*905]

 

 

 

 

 

 

 

 

 

Shipping Dimensions - In (mm)

24 3/4*24 3/4*36

32 3/4*32 3/4*32 1/2

32 3/4*32 3/4*36

32 3/4*32 3/4*36

32 3/4*32 3/4*40 1/2

32 3/4*32 3/4*36

32 3/4*32 3/4*40 1/2

W*D*H

 

[632* 632*919]

[832* 832*830]

[ 832* 832*930]

[832*832*930]

[832*832*1030]

[832*832*930]

[832*832*1030]

 

 

 

 

 

 

 

 

 

Net Weight - Lbs (kg)

156[71]

194[88]

198[90]

203[92]

231[105]

244[111]

258[117]

 

 

 

 

 

 

 

 

 

Approx Shipping Weight - Lbs (kg)

167[76]

209[95]

216[98]

220[100]

249 [113]

262[119]

282[128]

 

 

 

 

 

 

 

 

 

Table 6:System Cooling Capacity

Outdoor Unit

With This Indoor Air handler

 

 

 

 

Model Number

Air Handler

Compressor

Cooling Capacity (Btu/h)

SEER

Rated

 

 

brand

Sensible

Total

 

 

CFM(Outdoor)

HC18D1VAR

HB2400VD1M20

Bristol

13300

18000

 

13

1350.0

HC24D1VAR

HB2400VD1M20

Bristol

17700

24000

 

13

1800.0

HC30D1VAR

HB3600VD1M22

Bristol

20669

28000

 

13

2100

HC36D1VAR

HB3600VD1M22

Bristol

25900

35000

 

13

2700

HC42D1VAR

HB4800VD1M22

Bristol

29600

40000

 

13

3200

HC48D1VAR

HB4800VD1M22

Bristol

34800

47000

 

13

3600

HC60D1VAR

HB6000VD1M22

Bristol

40700

55000

 

13

4000

4

Page 6
Image 6
Haier HC18-60C1VAR, HC18-60A1VAR/S operation manual System Cooling Capacity, Model HC18-60D1VAR