Haier HC18-60D1VAR, HC18-60C1VAR, HC18-60A1VAR/S operation manual Specification, and electrical

Models: HC18-60A1VAR/S HC18-60D1VAR HC18-60C1VAR

1 17
Download 17 pages 43.73 Kb
Page 4
Image 4
3.SPECIFICATION

2

MODEL:

 

HC18A1VAR

HC24A1VAR

HC30A1VAR

HC36A1VAS

HC42A1VAR

HC48A1VAR

HC60A1VAR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit Supply Voltage

 

 

 

208/230-1-60

 

 

 

 

 

 

 

Normal Voltage Range

 

 

 

197 - 253

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor Brand

 

Bristol

 

Sanyo

Bristol

Sanyo

 

Bristol

Sanyo

Bristol

 

 

 

H20R

H29A

Minimum Circuit Amps

10.1

12.9

16.2

19.4

24.3

21.2

28.1

 

31.9

35.1

37.6

29.7

Max Fuse or Max CKT. BKR.

 

 

 

 

 

 

 

 

 

 

 

 

(HACR per NEC )

15

20

25

30

40

35

45

 

50

60

 

 

 

 

50

 

Rated Load Amps

7.4

9.6

11.8

14.4

18.3

15.8

21.3

 

24.4

26.9

28.9

22.6

Compressor

Locked Running

 

 

 

 

 

 

 

 

 

 

 

 

 

Amps

48

60

73

88

130

90

130

 

140

149

165

147

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Full Load Amps

0.86

0.86

1.4

1.4

1.43

1.43

 

1.43

 

 

Fan Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated HP

1/8

1/8

1/5

1/5

1/3

1/3

 

 

1/3

 

 

 

Nominal RPM

850

1000

1075

1075

1075

1075

 

1075

 

 

Liquid Line OD - In (mm)

3/8"[9.52]

3/8"[9.52]

3/8"[9.52]

3/8"[9.52]

3/8" [9.52]

3/8"[9.52]

3/8"[9.52]

 

Vapor Line OD - In (mm)

5/8"[15.88]

5/8"[15.88]

3/4"[19.05]

3/4"[19.05]

3/4"[19.05]

3/4"[19.05]

 

7/8"[22.2]

 

R-22 Charge -Oz (g)

49.47[1400]

63.60[1800]

88.34[2500]

93.64[2650]

115.19[3260]

122.97[3480]

128.27[3630]

137.81[3900]

141.34[4000]

Net Dimensions - In (mm)

23*23*24

23*23*24

23*23*31 1/2

23*23*31 1/2

30 1/4*30 1/4*31 1/2

30 1/4*30 1/4*31 1/2

30 1/4*30 1/4*35 1/2

W*D*H

 

[585 *585*605]

[585 *585*605]

[ 585 *585*805]

[ 585 *585*805]

[770 *770*805]

[ 770 *770*805]

[ 770 *770*905]

 

Shipping Dimensions - In (mm)

25*25*28 1/4

25*25*28 1/4

25*25*36

25*25*36

32 3/4*32 3/4*36

32 3/4*32 3/4*36

32 3/4*32 3/4*40 1/2

W*D*H

 

[632*632*719]

[632*632*719]

[632* 632*919]

[632* 632*919]

[832*832*930]

[ 832*832*930]

[832*832*1030]

 

Net Weight - Lbs (kg)

123[56]

125[57]

134[61]

141[64]

209[95]

198[90]

209[95]

 

200[91]

220[100]

216[98]

Approx Shipping Weight - Lbs (kg)

141[64]

143 [65]

158[72]

165[75]

231[105]

222[101]

231[105]

 

222[101]

246[112]

242[110]

The dimensions for the condensing unit are illustrated in Figure 1. Physical specifications are provided in Table 1 for 10 SEER systems respectively. Table 1: Model:HC18-60A1VAR/S

3.SPECIFICATION

and electrical

 

Page 4
Image 4
Haier HC18-60D1VAR, HC18-60C1VAR, HC18-60A1VAR/S operation manual Specification, and electrical