English

Materials

Use only 4 inch (10.2cm) diameter (minimum) rigid of flexible metal duct and approved vent hood which has a swing-out damper hat open when the dryer is in operation. When the dryer stops, the dampers automatically close to prevent drafts and the entrance of insects and rodents. To avoid restricting the outlet, maintain a minimum of 12 inches (30.5cm) clearance between the vent hood and the ground or any other obstruction. The vent flap should be able to move freely.

Although vertical orientation of the exhaust system is acceptable. Certain extenuating circumstances could affect the performance of the dryer:

1.Only rigid metal duct work should be used.

2.Venting vertically through a roof may expose the exhaust system to down drafts causing an increase in vent restriction.

3.Running the exhaust system through an area not insulated may cause condensation and faster accumulation of lint.

4.Compression of crimping of the exhaust system will cause an increase in vent restriction.

The exhaust system should be inspected and cleaned a minimum of every 12 months with normal usage. The more the dryer is used the more often you should check the exhaust system and vent hood for proper operation.

6

Page 7
Image 7
Haier CHLF103Q, HLF103Q/R, CGDE700AW user manual Materials