Haier HRF-288K Button inactive, Water spillage in refrigerator compartment, Troubleshooting

Models: HRF-288K

1 28
Download 28 pages 21.63 Kb
Page 28
Image 28
Button inactive

Water spillage in refrigerator compartmentAutomatic alteration on control panel Troubleshooting

Before calling for repair, make sure the following items:

Button inactive

●Disconnection of power supply

●Wrong button is pressed. (see the section "Functions")

Water spillage in refrigerator compartment

Water drain is blocked. Clear the path with the cleaning pin. (See section "Defrosting")

Cleaning pin

Automatic alteration on control panel

●Temperature display: disconnection of power supply or low voltage

●Fuzzy Operation mode: normal status

Prolonged operation period of the compressor

●Initial operation.

●Large quantity of food loaded. ●Hot weather.

●Door not properly closed.

●Improper setting of temperature (see the section "Operation")

Thick frost on the back of refrigerator

●Temperature is not properly set. See section "Operation" ●Door is not tightly closed.

●Door is frequently opened. ●Hot weather.

●Heavy moisture