Installation Manual of Room Air Conditioner
Read this manual before installation
Explain sufficiently the operating means to the user according to this manual.
Necessary Tools for Installation
1.Driver | 5.Torque wrench(17mm,22mm,26mm) | 9.Nipper | 12.Reamer |
2.Hacksaw | 6.Pipe cutter | 10.Gas leakage detector or |
|
3.Hole core drill | 7.Flaring tool |
| |
4.Spanner(17,19 and 26mm) | 8.Knife | 11.Measuring tape |
|
Drawing for the installation of indoor and outdoor units
Accessory parts
No. | Accessory parts | Number | |||
of | |||||
|
|
|
| articles | |
1 | Remote controller | 1 | |||
2 |
| 2 | |||
3 |
|
|
| 1 | |
|
|
| Mounting plate |
| |
4 |
|
| Drain hose | 1 | |
|
|
|
| ||
5 |
|
| 4X50 | 6 | |
Steel nail, cement | |||||
|
| ||||
6 | 4X25 | Plastic cap | 4 | ||
| Screw |
|
| ||
|
|
|
| ||
7 |
|
| Screw | 6 | |
8 |
|
| 1 | ||
|
|
|
| ||
9 |
|
| Cover | 1 | |
10 |
|
| Cushion | 4 | |
11 | Connecting cable | 1 | |||
12 | Change for | 1 | |||
fresh air box | |||||
|
| ||||
13 | Change for | 1 | |||
|
|
|
Optional parts for piping | more | than | 10cm | |
| ||||
|
|
|
| |
Mark | Parts name |
|
|
|
A
BAdhesive tape
CSaddle(L.S) with screws
DConnecting electric cable for indoor and outdoor
EDrain hose
FHeating insulating material
G Piping hole cover
Arrangement of piping directions
| Rear left |
Left | Rear |
| right |
| Right |
| Below |
more than 5cm
more | than |
|
| 10cm | |
|
|
G
more | than | 10cm |
| ||
|
|
F
Attention must be paid to | A |
the rising up of drain hose |
C
| than | 10cm |
more |
| |
|
|
| fresh air |
|
14 | tube(suit) | 2 |
Outlet joint | ||
15 | Outlet joint | 1 |
12
13
D
E
Note:1.Cooling only units don't have
2. 14 is only for the models of 18,22.
3.The models ZF don't have fresh function and accessory parts related with freshing.
| than | 60cm |
|
|
more | more |
|
| |
|
|
| ||
|
| than | 15cm | |
|
|
| ||
|
|
|
|
| The marks from A to G in the figure are the parts numbers. |
No.0010554405B | The distance between the indoor unit and the floor should |
be more than 2m. |