Haier HSU-24HD0307, HSU-24HK0307 installation manual Installation Manual of Room Air Conditioner

Models: 0010554405B HSU-24HD0307 HSU-24HK0307

1 8
Download 8 pages 55.68 Kb
Page 1
Image 1
Installation Manual of Room Air Conditioner

Installation Manual of Room Air Conditioner

Necessary Tools for Installation Read this manual before installation

Manual background Explain sufficiently the operating means to the user according to this manual.

Necessary Tools for Installation

1.Driver

5.Torque wrench(17mm,22mm,26mm)

9.Nipper

12.Reamer

2.Hacksaw

6.Pipe cutter

10.Gas leakage detector or

 

3.Hole core drill

7.Flaring tool

soap-and-water solution

 

4.Spanner(17,19 and 26mm)

8.Knife

11.Measuring tape

 

Drawing for the installation of indoor and outdoor units

Accessory parts

No.

Accessory parts

Number

of

 

 

 

 

articles

1

Remote controller

1

2

 

R-03 dry battery

2

3

 

 

 

1

 

 

 

Mounting plate

 

4

 

 

Drain hose

1

 

 

 

 

5

 

 

4X50

6

Steel nail, cement

 

 

6

4X25

Plastic cap

4

 

Screw

 

 

 

 

 

 

7

 

 

Screw

6

8

 

 

Drain-elbow

1

 

 

 

 

9

 

 

Cover

1

10

 

 

Cushion

4

11

Connecting cable

1

12

Change for

1

fresh air box

 

 

13

Change for

1

 

 

 

Optional parts for piping

more

than

10cm

 

 

 

 

 

Mark

Parts name

 

 

 

ANon-adhesive tape

BAdhesive tape

CSaddle(L.S) with screws

DConnecting electric cable for indoor and outdoor

EDrain hose

FHeating insulating material

G Piping hole cover

Arrangement of piping directions

 

Rear left

Left

Rear

 

right

 

Right

 

Below

more than 5cm

more

than

 

 

10cm

 

 

G

more

than

10cm

 

 

 

F

Attention must be paid to

A

the rising up of drain hose

C

 

than

10cm

more

 

 

 

 

fresh air

 

14

tube(suit)

2

Outlet joint

15

Outlet joint

1

12

Manual backgroundManual background 13

D

E

Note:1.Cooling only units don't have Drain-elbow

2. 14 is only for the models of 18,22.

3.The models ZF don't have fresh function and accessory parts related with freshing.

 

than

60cm

 

 

more

more

 

 

 

 

 

 

 

than

15cm

 

 

 

 

 

 

 

 

The marks from A to G in the figure are the parts numbers.

No.0010554405B

The distance between the indoor unit and the floor should

be more than 2m.

Page 1
Image 1
Haier HSU-24HD0307 installation manual Installation Manual of Room Air Conditioner, Necessary Tools for Installation