User LED Indications

LED Indication

Cause

 

 

 

 

Green Solid

Charging

Green Flash

Good read

 

 

Red Solid

Error condition

 

 

Red Flashing

Low battery

 

 

Audio Sound

An audio signal (default ON) provides a quick indication if a scan passes or fails the current test. You can change the pitch/volume of these beeps (see Illumination Timer on page B-1). After a scan, one short, high pitch beep indicates that the symbol passes an appropriate group of tests, while one long, low pitch beep indicates that it fails.

Special Features

The QC890 Verifier supports the Reflectometer mode. In the Reflectometer mode, the unit operates as a free-running reflectometer. See "Reflectometer Mode" on page 3-7for additional information.

Physical Connections

A DC power barrel on the back of the unit connects to a power supply for external power and battery charging.

The DB9 port on the unit connects to the pen wand, mouse wand, or customized imager. Refer to "Scanning Properly Using the QC3800V Linear Imager:" on page 3-5. If you are using any of these devices, refer to "Scanning Properly Using a Pen/Mouse Wand" on page 3-3for additional information.

The RJ45 ten pin connector provides the USB or RS-232 serial interface to the host. Refer to "USB Communication Interface" on page 2-1and "RS-232 Serial Communication Interface" on page 2-3for details on connecting your unit.