Hans Grohe 06550XX0, II, 06549XX0 English Check valve maintenance, Clean the cartridge filters

Models: 06564XX0 I 06565XX0 0657000 06573000 06550XX0 II 06549XX0

1 36
Download 36 pages 43.15 Kb
Page 16
Image 16

English

Check valve maintenance

The check valve should be removed and inspected yearly.

If the check valve is damaged, replace it.

check valve

Clean the cartridge filters

If the water pressure decreases as the water is made warmer, clean the cartridge filters.

Turn the water off at the main.

Remove the handle.

Hold the cartridge stop unit steady with a 36 mm wrench.

Hold the stop unit steady while removing or installing the thermo- stat cartridge.

Failure to do so may result in damage to the stop unit.

Use a 24 mm wrench to unscrew the thermostatic cartridge from the stop unit.

Clean the filters under running water. Use a soft tooth- brush to remove stubborn deposits.

Lightly lubricate the cartridge o-rings with white plumbers grease.

Install the thermostat cartridge.

Justify and install the handle.

filters