Initial Tool Set Up/Assembly

Initial Tool Set Up/Assembly

y fet Sa

p

Read the entire Important Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of this product.

To prevent serious injury:

Operate only with proper spark arrestor installed.

Operation of this equipment may create sparks that can start fires around dry vegetation.

A spark arrestor may be required. The operator should contact local fire agencies for laws or regulations relating to fire prevention requirements.

At high altitudes, the engine’s carburetor, governor, and any other parts that control the fuel-air ratio will need to be adjusted by a qualified mechanic to allow efficient high-altitude use and to prevent damage to the engine and any other devices used with this product.

CAUTION: This generator is not intended to power sensitive electronic equipment without the addition of an appropriate line conditioner and surge protector (both not included). Sensitive electronic equipment includes, but is not limited to, audio/video equipment, some television sets, computers, and printers. Sensitive electronic equipment should be operated on approved inverter type generators or pure sine wave generators.

Setu

Note: For additional information regarding the parts listed in the following pages, refer to the Assembly Diagram near the end of this manual.

Note: Wheel Kit, item # 68531 (sold separately) can be used with this generator.

Grounding

ratiepO

The Generator must be properly grounded before use. Have the unit grounded by a qualified electrician if you are not qualified to do so.

To ground the Generator, connect a #6 AWG grounding wire (not included) from the Grounding Terminal on the Control Panel to a grounding rod (not included) that has been driven at least 24 inches deep into the earth. The grounding rod must be an earth-driven copper or brass rod (electrode) which can adequately ground the Generator.

ec

Operating Instructions

Read the entire Important Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of this product.

Inspect tool before use, looking for damaged, loose, and missing parts.

If any problems are found, do not use tool until repaired.

Generator Pre-Start Checks

Maintenan

Inspect engine and equipment, looking for damaged, loose, and missing parts before set up and starting. If any problems are found, do not use equipment until fixed properly.

Checking and Filling Engine Oil

2.Close the Fuel Valve.

3.Clean the top of the Dipstick and the area around it. Remove the Dipstick by threading it counterclockwise, and wipe it off with a clean lint free rag.

CAUTION! Your Warranty is VOID if the engine’s crankcase is not properly filled with oil before each use.

Before each use, check the oil level. Do not run the engine with low or no engine oil.

Full level

y fet Sa Full level

Running the engine with no or low engine oil WILL permanently damage the engine.

1. Make sure the engine is stopped and is level.

4.Reinsert the Dipstick without threading it in and remove it to check the oil level. The oil level should be up to the full level as shown above.