TABLES A and B

RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION

CORDS* (120/240 VOLT)

NAMEPLATE

AMPERES

(at full load)

0 – 2.0

2.1– 3.4

3.5– 5.0

5.1– 7.0

7.1– 12.0

12.1– 16.0

16.1– 20.0

TABLE A

EXTENSION CORD LENGTH

25’

50’

75’

100’

150’

18

18

18

18

16

18

18

18

16

14

18

18

16

14

12

18

16

14

12

12

18

14

12

10

-

14

12

10

-

-

12

10

-

-

-

 

 

 

 

 

* Based on limiting the line voltage drop to five volts at 150%

of the rated amperes.