TABLES A and B
RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION
CORDS* (120/240 VOLT)
NAMEPLATE
AMPERES
(at full load)
0 – 2.0
2.1– 3.4
3.5– 5.0
5.1– 7.0
7.1– 12.0
12.1– 16.0
16.1– 20.0
TABLE A
EXTENSION CORD LENGTH
25’ | 50’ | 75’ | 100’ | 150’ |
18 | 18 | 18 | 18 | 16 |
18 | 18 | 18 | 16 | 14 |
18 | 18 | 16 | 14 | 12 |
18 | 16 | 14 | 12 | 12 |
18 | 14 | 12 | 10 | - |
14 | 12 | 10 | - | - |
12 | 10 | - | - | - |
|
|
|
|
|
* Based on limiting the line voltage drop to five volts at 150%
of the rated amperes.