Incorrect line voltage: Check the line voltage and, if insufficient, have a licensed electrician remedy the situation.

Wire Feeds, but arc does not ignite

Possible Causes and Solutions:

Improper ground connection: Make certain that the work piece is contacted properly by the Ground Clamp and that the work piece is properly cleaned near the ground clamp and the welding location.

Improperly sized or excessively worn Contact Tip:

Verify that Contact Tip is the proper size for the welding wire used. Check that the hole in the tip is not deformed, enlarged, or dirty. If needed, replace Contact Tip with proper size and type.

Wire Feeds, but Shielding gas does not Flow

Possible Causes and Solutions:

Empty Gas Cylinder: Check gas cylinder.

Nozzle Plugged:

Clean nozzle. If damaged, replace.

Regulator or cylinder valve closed: Make sure both valves are adjusted properly.

Gas line blocked:

Check external hose, and hose within Torch cable.

Gas solenoid broken or not connected properly:

Have a qualified technician check/ replace.

PLEASE READ THE FOLLOWING

CAREFULLY

The manufacturer and/or distributor has provided the parts listandassembly diagram in this manual as a reference tool only. Neither the manufacturer or distributor makes any representation or warranty of any kind to the buyer that he or she is qualified to make any repairs to the product, or that he or she is qualified to replace any parts of the product. In fact, the manufacturer and/or distributor expressly states thatall repairsand parts replacements should be undertaken by certified and licensed technicians, and not by the buyer. The buyer assumes all risk and liabilityarising out of his or her repairs to the original product or replacement parts thereto, or arising out of his or her installation of replacement parts thereto.