12Venting
| |
| side only. If two covers are |
Hole with a minimum | used, each must be mounted |
clearance of 18" (450 mm) | on |
between connector and wall. | at least 7/8" (21mm) away |
| from the wall. |
1" (25mm) Clearance
AN APPROVED CANADIAN
WALL
The Chimney
This unit must be installed into a chimney approved for use with
In Canada, this unit is listed for use with prefabricat- ed chimneys tested and listed to the high temperature (650 degrees C) chimney standard, ULC
Closest | Minimum 2" (50mm) | |
Combustible | ||
Material | Clearance to Brick | |
| Liner | Minimum 12" |
| (300mm) to Brick | |
|
| |
| Flue | Fire Clay |
| Thimble | |
|
| |
| Chimney | Chimney |
|
|
Connector
Masonry Chimney Built to
NFPA 211 Specifications.
Minimum 12" (300mm)
to Combustibles AN APPROVED U.S.
WALL
Do not connect this unit to a chimney flue servicing another appliance.
This VF3000 Is Approved To Burn Anthracite “Rice” Coal Only.
The minimum recommended height for any chimney is 16 ft (4.8 m) above flue collar height. A round flue (either masonry or approved prefabricated), of either 6" (150 mm), 7" (180 mm) or 8" (200 mm) may be used. For square or rectangular masonry chimneys, nominal sizes of 8" x 8" or 8"x 12" (200mm x 200 mm, 200 mm x 300 mm) may be used.
Codes require that
m)above the highest point within a 10 ft (3 m) radius. Thus, the 3 foot, 2 foot, 10 foot rule:
3ft. - Above roof exit point
2ft. - Higher than anything within- 10ft. of the chimney.
More Than 10 ft. (3m)
10 ft. (3m)
2 ft. (0.6m) min.
Ridge
Height Necessary Above Any Roof Sur- face Within 10ft. (3m)
3ft. (0.9m) minimum above exit
point
Chimney
The