Verti-Flow™ Stoker Control

17

0.5 A

MAX LOAD

COMPONENT

0.75 A 1.25 A

MAX LOAD MAX LOAD

RECEPTACLES - ON SIDE

 

 

 

VERTI - FLOW ™

STOKER CONTROL

Verti-FlowStoker Control

This section describes the features and operations of the Harman Verti-FlowStoker Control. The timers are adjustable from 0 minutes to 15 minutes in 1 minute steps. There are red lights on the front panel to show proper op- eration of the timer. One indicator shows power is applied to the unit. The other three indicators show when power is available at the adjacent receptacle.

The stoker control will be mounted on the side panel of the feeder directly below the coal hopper. The three re- ceptacles and switch will be facing forward while the power cord, 3 AMP fuse access port and the thermostat connections will be to the rear.