Room Sensor and Air Grill Installation

Room Sensor Installation

Gold Air Grill Installation

Fig. 16

Fig. 17

The room sensor is a small temperature sensor on the end of a 60" gray wire. This sensor is installed much like a standard wall thermostat. Because it is so small, it can be hidden along the trim of a doorway or even up the leg of a coffee table. There is a remote room sensor port on the rear of the unit for easy exter- nal connection. Use standard 18-2 thermostat wire to extend the distance to the desired location (100' maxi- mum). The room sensor should be installed in the lo- cation where you want to control the temperature.

NOTE: Distances of more than 25 feet from the unit or in another room are not recommended. It is recommended that the room sensor be installed, even if only installed on the rear of the unit as a return air sensor. The room sensor is essential for the Advance's excellent efficiency.

Insert the two tail end hooks of the Air Grill Assembly up under the stove top edge. Insert inward until the two center hooks drop into the stove body slots in the front of the unit.

REMINDERS

Hopper Lid

Foam Gaskets

Fig. 18

Do not allow pellets or sawdust to build up on the hopper lid gasket.

Inspect the hopper lid gasket for damage. A good hopper lid seal is very important for proper operation.