Harman Stove Company Advance Pellet Stove manual Advance Motor & Component Locations

Models: Advance Pellet Stove

1 31
Download 31 pages 27.02 Kb
Page 25
Image 25

Advance Motor & Component Locations

 

Igniter Wire - Feeder Entry Location

Feeder Chain

Igniter Wire Loop (Cold Leads)

Feeder Gear motor

Combustion Air

Intake Backdraft Damper

25 25

 

Low Draft

Combustion Motor

Pressure

Switch

 

 

ESP Probe

Distribution Blower

 

Advance Pellet Stove Safety Devices

 

The Combustion Motor Fuse is a thermal overload

The Control Board/ESP combination is responsible for

The Low Draft Pressure Switch is a differential pres-

one-time fuse link within the motor windings. Should the distri-

all high limit safety control. There are 2 high limits, one normal

sure switch that senses the pressure between the firebox

bution motor fail with the unit operating over 80%, this fuse will

operation high limit and one backup high limit. The control has

and the room. If the pressure becomes too low for proper

protect the other components by melting off at a set tempera-

an automatic diagnostic circuit that continuously monitors the

combustion, the switch opens, cuttin power to the feeder mo-

ture. With the fuse blown, the combustion motor will stop.In

ESP and Room Sensor for faults. If a fault should occur, the

tor and the igniter element. This switch is connected into the AC

turn, the feeder motor will not operate and the stove will go out.

control sends a status alert and at the same time the unit goes

(high voltage) wires; therefore, the control may show the feeder

This may only happen when the unit is on Maximum (#7 on the

down to minimum feed/minimum burn as a safety condition.

motor and igniter lights "on" but they are not operating.

Temperature Dial, #6 on the Feed Adjuster and Distribution blower

 

 

 

not operating). If this fuse does blow, the unit will need service.

 

 

 

Page 25
Image 25
Harman Stove Company Advance Pellet Stove manual Advance Motor & Component Locations