Harman Stove Company R6 owner manual When to use Stove Temp Mode, When to use Room Temp Mode

Models: R6

1 13
Download 13 pages 2.38 Kb
Page 12
Image 12
When to use "Stove Temp Mode"

Fig. 13

This setting will produce medium heat with the distribution blower on "low".

This setting will produce a room temperature of 70 degrees with the distribution blower at medium speed.

This setting will produce continuous maximum heat output with the distribution blower at full speed.

When to use "Stove Temp Mode"

In "Stove Temp Mode" the Stove Temp Dial determines the temperature of the stove. Heat output and fuel consumption will remain con- stant. This makes it possible to tell how long a hopper full of pellets will last. The distribution blower speed will vary according to the position of the mode selector, fig. 13.

When to use "Room Temp Mode"

In "Room Temp Mode" heat output is controlled automatically by the Room Sensing Probe. When the Room Sensing Probe calls for heat, the stove will increase output. When the Room Sensing Probe is getting close to the set temperature, the stove will begin to level off output and keep the fire burning at just the right temperature to maintain that setting.

High output is determined by the feed rate. The maximum feed rate should be set for 1" of ash in front of fire.

In "Room Temp Mode" fuel consumption is sac- rificed for exact room temperature. Therefore, as it gets colder more pellets will be burned automati- cally.

The distribution blower speed will vary accord- ing to the position of the mode selector, fig. 13.

Shut-Down Procedure

To kill the fire or stop burning the stove, turn the Mode Selector to "OFF". This will cause the fire to diminish and burn out. When the fire burns out and the stove cools down everything will stop.

If you pull the plug to shut down the stove, all motors will stop. This may cause incomplete com- bustion and smoke in the firebox. If the load door is opened the smoke may escape.

The best way to shut down the stove is simply let it run out of pellets, then the stove will shut down automatically.