Harman Stove Company R6 #6 Installing into an existing fireplace chimney US and Canada

Models: R6

1 13
Download 13 pages 2.38 Kb
Page 8
Image 8
#6 Installing into an existing fireplace chimney ( US and Canada )

#6 Installing into an existing fireplace chimney ( US and Canada )

This method provides excellent venting for nor- mal operation. This method also provides natural draft in the event of a power failure.

In Canada and some places in the US it is re- quired that the vent pipe extend all the way to the top of the chimney.

In this method a cap should also be installed on the chimney to keep out rain. Be sure to use approved pellet vent pipe fittings. Seal pipe joints with silicone in addition to the sealing system used by the manu- facturer. Pipe size should be increased to 4" using this method.

Fig. 9

#7 Installing into an existing chimney ( US and Canada )

This method provides excellent venting for nor- mal operation. This method also provides natural draft in the event of a power failure.

In Canada and some places in the US it is re- quired that the vent pipe extend all the way to the top of the chimney. The pipe or liner inside the chim- ney should be 4"diameter.

In this method a cap should also be installed on the chimney to keep out rain. One disadvantage of this method is that it is harder to clean the vent pipe, therefore, there is a tendancy not to do it as often as needed.

Fig. 10

8

Page 8
Image 8
Harman Stove Company R6 owner manual #6 Installing into an existing fireplace chimney US and Canada