Operation

Exception F200 Wood Insert

Operation

General Considerations

Draft

Before you install and operate your Exception wood insert, please read the entire contents of this manual. Pay particular attention to the explanation of draft and its

effect on insert performance in the Installation section. By following the installation and operating guidelines, you will ensure proper draft and gain maximum efficiency and enjoyment from your insert.

Fuel

Your Exception burns wood very efficiently. Here are some guidelines concerning log size and moisture con- tent that will help you obtain the best performance.

Select hardwoods if possible, as they are heavier and contain more heating capacity (BTU’s) per load than

do softwoods. Wood should be split and stored under cover for “seasoning” - a year is recommended. Your

insert is not an incinerator - do not burn garbage, painted or treated wood, plastic, or other debris.

Keep the area around the insert free from clut- ter. Keep allcombustibles, including fuel, beyond the code- required clearance distance (48" or 1215 mm in the U.S., 1525 mm or 60" in Canada). Never store fuel in front of the insert where it could interfere with door operation, safe loading, and ash removal.

Do not burn garbage or flammable fluids such as gasoline, naptha, or engine oil.

The door must be closed while the insert is in nor- mal operation, and the gaskets routinely examined for wear and replaced when necessary. Good door seals are important for maintaining control of the insert. Operating the insert with the door inadequately sealed, could create a serious over firing condition (discussed later in this sec- tion).

The glass used in your Exception is manufactured to exact standards to withstand the high heat of the fire, but like all glass, it must be treated with common sense and care. Never abuse the glass by slamming the door shut or striking the glass with a heavy object. If the glass is broken or damaged, do not operate the insert until it has been replaced (See instructions in the Maintenance sec- tion.)

Operating As A Fireplace

To operate as a fireplace, open the damper and keep it open. Next, open the door and place the optional screen (part number 3-40-727336) over the door opening. Check for smoke spillage into the room. If smoke is escaping into the room, remove the screen and close the door. Al- ways wear gloves when placing or removing the screen.

Never leave the unit unattended with the door open.

Andirons

The andirons keep the fuel from coming in direct contact with the glass, and keep hot coals and embers from spilling out while reloading. Never build a fire di- rectly against the glass.

Do not use a grate or elevate the fire. Build wood fire directly on insert hearth.

The Insert

Doors

Your insert has a large glass-paneled door for loading and fire viewing. To open the glass door, turn the handles clockwise and pull out; to close the door, return the handles to an open 9 o'clock closed 6 o'clock, and push in to engage the latch while turning the handles counterclockwise.

If the latch on your Exception door needs adjust- ment, follow the instructions given in the Maintenance section of this manual.