Warning: Do notinstall in sleeping room.

 

 

 

 

Exception F200 Wood Insert

Warning: Do notinstall in sleeping room.

 

Floor Protection

 

 

 

In all installations, the area under and around the

 

 

 

insert must be protected from falling ash and live coals.

 

 

 

This protector must be of noncombustible material, and

 

 

 

positioned as shown in the accompanying illustration.

 

 

 

The guidelines for the floor protection are in both

 

 

 

USA and CANADA: 8"(200mm) to each side of the door

 

 

 

opening, and:

 

 

 

 

In USA:

16" of non-combustible material in front

8"

16"USA

 

 

of the door opening.

 

 

 

 

 

18"Canada

Wall

In CANADA: (1) If the floor surface is 0" - 4 1/2"(114

 

 

 

 

 

Floor Protector

 

 

 

mm) below the insert base, 18"(450mm)

22"

 

 

of 1/2"(12.7mm) thick, k=.84 thermal

 

 

 

protection is required in front of the door

 

559mm

 

 

opening.

 

 

 

 

(2) If the floor surface is greater than 4

 

 

 

 

1/2"(114mm) below the base of the

 

 

 

 

insert, 18"(450mm) of non-combustible

 

 

 

 

material in front of the door is required.

 

 

 

 

See appendix A.

Mantel

Clearances

 

 

 

 

Clearance is the empty space required between the

 

insert and the nearest combustible surface or object, such

2 4" ( 61 0 mm ) as walls, ceilings, floors, or furniture. Clearance distances

with hood

may only be reduced by using methods approved by ei-

36" (900 mm)

without hood

ther the CAN/CSA B365 standard (Canada) or NFPA

 

211 (U.S.) Contact your building authority for informa-

 

tion if you are interested in reducing clearance distances

 

other than those presented here.

 

 

From the front of the insert, clearance to combus-

 

tible materials such as furniture, curtains, fuel, etc., is:

 

48"(1215 mm) in the U.S. and

60"

 

(1525 mm) in Canada.

 

 

The clearance to combustibles from the top of the

 

unit to the mantel must be 24" (610 mm), if using the op-

 

tional hood, and at least 36" (900 mm) if the hood is not

 

used.

 

Floor Protection Notch

The blower cord can be routed to either side after removing the ash lip and base cover. Route the cord to right or left by placing the cord in the proper notch shown above.

Do Not Connect This Unit To A Chimney Serving Another Appliance

Masonry Fireplace Requirements

1.The chimney must be at least 15 feet high but not more than 33 feet high.

2.This room heater must be connected to a code approved masonry chimney with a clay tile or stainless steel flue liner.

3.The entire fireplace and chimney must be clean and in good condition. Any damage must be repaired before installing the insert. A stainless steel liner may be in- stalled if the tile liner of the masonry chimney is dam- aged.

4.The fireplace and chimney must meet local building

codes.11