Harmar Mobility CPL1000, CPL600, CPL1400 EMI and Flush Strike Interlocks optional, EMI Interlock

Models: CPL1200 CPL400 CPL1000 CPL800 CPL600 CPL1400

1 22
Download 22 pages 25.01 Kb
Page 14
Image 14

14

EMI and Flush Strike Interlocks (optional)

The optional EMI or Flush Strike Interlocks are provided with a combination mechanical lock and electric contact. They are to be used with existing doors.

The interlock:

Prevents the lift from running if the door is not closed.

Prevents the door from being opened if the platform is not at the landing.

Unlocks when the lift is on the landing limit switch.

Flush Strike Interlock

Refer to the instructions inside the strike box for mounting requirements.

EMI Interlock

1)Position interlock to door jamb and mark mounting holes.

2)Fasten Interlock to door jamb with #8 wood screws.

3)Route 4-conductor Interlock cable thru hole in top of interlock and make wire connections.

4)Attach door keeper and emergency key plates to hoistway door.

.

A length of multi‐conductor wire will need to be ran from the bottom of the lift tower to the interlocks. Consult local codes for type and mounting requirements. After wiring is completed, the wiring harness must be plugged into it appropriate receptacle on the controller (ref pg 5).

Wiring Connections

Flush Strike

Lift Harness

Yellow / *Black

Black

Yellow / *Purple

Green

White

White

Orange

Orange

Blue

Blue

Brown

Brown

*Colors when used on a DC (battery) powered lift option.

EMI

Lift Harness

Black (A)

Black

Black (B)

Green

Yellow (C)

White

Yellow (D)

Orange

N/A

*Blue

N/A

*Brown

*Must be tied together when using an EMI Interlock.