HeadsetUSA PAS 400 manual Ground Lift Switch, Fuses 3, Power Switch

Models: PAS 400

1 21
Download 21 pages 45.11 Kb
Page 8
Image 8

1.6 GROUND LIFT Switch (2)

The signal GROUND LIFT switch should be set to the GROUND position. If the PAS 400 hums when connected to other equipment, setting the switch to the GROUND LIFTED position may reduce or eliminate the hum.

1.7 Fuses (3) and (4)

Disconnect the PAS 400 from any external power supply (mains or battery) before changing or inspecting fuses.

Only the following fuse types can be used

1A

Slo-Blo

for 230 Volt AC / 50 Hz models

2A

Slo-Blo

for 120 Volt AC / 60 Hz

2A

Slo-Blo

for 100 Volt AC / 50-60 Hz

6.3A Slo-Blo

for the rechargeable battery

1.8 Powering with a 12-16 Volt DC External or Auto Battery (5)

The "EXT BATTTERY 12 - 16 VDC" socket is accessible by removing the sealing cap.

A plug-in connector for this is socket available. Please note the correct polarity (labelled as "+" and "-" by the socket). Incorrect polarity will not cause damage, but the internal battery will then power the PAS 400.

1.9 Power Switch (6)

The power switch has three positions:

Position 0

Loudspeaker system is Off

 

Battery will charge (if connected

 

to a power supply)

 

 

Position I

Loudspeaker system is On

 

Wireless receiver is On

 

Battery will charge (if connected

 

to a power supply)

 

 

Position II

Loudspeaker system is On

 

Wireless receiver is Off

 

Battery will charge (if connected

 

to a power supply)

 

 

When the system is switched On (to Position I or Position II), there is an automatic 3-second delay before it is operational.

When the (optional) built-in wireless receiver is not being used, set the Power Switch to Position II to conserve battery power and to get the longest run-time per charge.

When switching from Position I to Position II (or visa versa), first switch to Position 0 and wait 5 seconds before switching to the next position, otherwise, the Deep Discharge Cut-Off Circuit may be activated (if activated, switch to Position 0 and wait 30 seconds before switching to Position I or II.).

8 freePORT PAS 400 Version 060328

Page 8
Image 8
HeadsetUSA PAS 400 manual Ground Lift Switch, Fuses 3, Powering with a 12-16 Volt DC External or Auto Battery, Power Switch