OPERATION INSTRUCTIONS

Preweighing the Stretcher

1.Make sure the scale is free of load (nothing is hanging from it), including the stretcher.

2.Press the ON/OFF button to turn the scale on.

3.Wait until ”000Lb00oz” and “ZERO” on the left side of the display will appear. The scale will remember the last amount that was tared, so if the weight of the stretcher had previously been tared, the scale will display a negative weight when it is turned on again.

Note: The ‘ZERO’ sign will show on the upper left side of the display only when the scale is free of load, including the stretcher.

4.If the weight of the stretcher is known, enter the TARE value according to instructions in the “Menu”, para 02. If the stretcher’s weight is unknown, place the stretcher only on the scale; press REWEIGH. Enter the Automatic TARE by pressing the TARE button. Display will read ”000Lb00oz”.

Note: Once the tare is set the “TARE” sign will appear in the upper right side of the display.

Placing Patient in Stretcher

1.After setting the stretcher’s weight as tare, take the stretcher off the lifter. The display will now show a negative weight, equivalent to the weight of the stretcher.

2.Lay the stretcher on a bed or on any other stable surface you can use to lay the patient you wish to weigh.

3.Carefully move the patient to a lying position on the stretcher.

Note: lay the patient’s center mass as close as you can to the center of the stretcher.

4.Wheel the lifter scale close to the stretcher and lower the boom with the hoops as far as 5- 10” (12 cm -25 cm) from the patient’s body.

5.Connect the four hanging loops of the stretcher to the four hooks at the end of each Stretcher Hoop, making sure that the loops are hanging freely from the four hooks.

Note: Make sure both hooks connecting the load cell assembly beam lie on the lifter boom. If only one of the hooks lies on the beam it can cause inaccurate readings of weight.

6.Tighten the hydraulic control valve knob by turning it clockwise. The control valve knob is located on the Pump near the Pump handle.

7.Use the Base Adjustment Lever to widen the Lifter Base. The Base must be spread to the widest possible position to maximize stability.

8.Pump the hydraulic Pump handle to lift the Stretcher and patient until the entire Stretcher is hanging from the Stretcher Hoops and is not touching the bed or any other object. Do not lock the Wheel on the Lifter Base. If needed, the Base will move slightly to adjust for balance.

Caution: Never move patient away from bed or leave patient unattended.

Taking Weight Measurements

1.The scale will calculate the patient’s weight. Depending upon the movement of the stretcher, the scale may take several seconds to lock into the weight. We recommend reweighing after the patient is lying still on the stretcher by pressing the REWEIGH button.

2.After weight measurement is obtained and recorded, lower the Stretcher and the patient to the bed. Open the hydraulic pump control valve knob by turning it counterclockwise very slowly to control the descent.

3.Guide the patient and Stretcher down onto the bed.

11

Page 12
Image 12
Health O Meter 2000KL operation manual Operation Instructions

2000KL specifications

The Health O Meter 2000KL is a sophisticated and reliable weighing scale designed for professional healthcare settings, such as hospitals and clinics. With a sleek and sturdy design, this scale caters specifically to the needs of medical professionals who require accurate and efficient patient assessments.

One of the standout features of the Health O Meter 2000KL is its high weight capacity. With the ability to measure individuals weighing up to 550 pounds, it accommodates a diverse patient population. This ensures that healthcare providers can rely on a single device to cater to various body types and sizes, which is essential in maintaining a standard of care.

The 2000KL model incorporates a large, easy-to-read digital display that provides quick weight readings. The display is backlit to improve visibility, especially in low-light environments. This feature guarantees that practitioners can obtain measurements swiftly, which is crucial during busy patient visits.

In terms of technology, the Health O Meter 2000KL utilizes advanced load cell technology, which offers precise measurements and stability. This technology minimizes the impact of external factors that could skew weight readings, thus enhancing the accuracy of weight assessments. Furthermore, the scale also comes equipped with automatic shut-off features to conserve battery life, making it economical for continuous use in clinical environments.

Another significant characteristic of the 2000KL is its user-friendly interface. Healthcare professionals can quickly operate the scale without extensive training, which allows for seamless integration into clinical workflows. It features a low-profile platform that enables easy access for patients, particularly those with mobility issues.

Moreover, the Health O Meter 2000KL is built with safety and durability in mind. Its robust construction ensures long-term reliability, maintaining accuracy and performance under the demands of a busy healthcare setting. The non-skid surface of the platform also promotes patient safety by preventing slips during weighing.

In conclusion, the Health O Meter 2000KL stands out as a high-quality, reliable weighing scale that combines innovative technology with practical features. Its high capacity, accurate load cell technology, easy-to-read display, and user-friendly design make it an excellent choice for healthcare providers focused on delivering efficient and accurate patient care. This device not only streamlines the weighing process but also enhances the overall patient experience in clinical settings.