Safety Alert Key:

DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.

WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.

CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE: Used to address practices not related to personal injury.

Table of Contents

A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 B. Limited Lifetime Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . 5

1 Listing and Code Approvals

A. Appliance Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 B. Tempered Glass Specifications . . . . . . . . . . . . . . . . . . . . . 7 C. BTU Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 7 E. Non-Combustible Materials Specification. . . . . . . . . . . . . . 7 F. Combustible Materials Specification . . . . . . . . . . . . . . . . . 7 G. Electrical Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 H. Requirements for the Commonwealth of Massachusetts. . 8

User Guide

2 Operating Instructions

A. Gas Fireplace Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 B. Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 C. Fan Kit (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 D. Clear Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 E. Decorative Doors and Fronts . . . . . . . . . . . . . . . . . . . . . . 10 F. Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 G. Remote Controls, Wall Controls and Wall Switches. . . . . 10 H. Before Lighting Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . 10 I. Lighting Instructions (IPI) . . . . . . . . . . . . . . . . . . . . . . . . . 11 J. Lighting Instructions (Standing Pilot) . . . . . . . . . . . . . . . . 12 K. After Fireplace is Lit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 L. Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . 13

3 Maintenance and Service

A. Maintenance Tasks-Homeowner . . . . . . . . . . . . . . . . . . . 14 B. Maintenance Tasks-Qualified Service Technician . . . . . . 15

Installer Guide

4 Getting Started

A. Typical Appliance System. . . . . . . . . . . . . . . . . . . . . . . . . 17

B. Design and Installation Considerations . . . . . . . . . . . . . . 18

C. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . . 18

D. Inspect Appliance and Components. . . . . . . . . . . . . . . . . 18

5 Framing and Clearances

A. Selecting Appliance Location . . . . . . . . . . . . . . . . . . . . . . 19

B. Constructing the Appliance Chase . . . . . . . . . . . . . . . . . . 20

C. Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

D. Mantel and Wall Projections. . . . . . . . . . . . . . . . . . . . . . . 21

6 Termination Locations

A. Vent Termination Minimum Clearances . . . . . . . . . . . . . . 22

7 Vent Information and Diagrams

A. Approved Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

B. Vent Table Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

C. Use of Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

D. Measuring Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

E. Vent Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

8 Vent Clearances and Framing

A. Pipe Clearances to Combustibles . . . . . . . . . . . . . . . . . . 34 B. Wall Penetration Framing. . . . . . . . . . . . . . . . . . . . . . . . . 34 C. Install the Ceiling Firestop . . . . . . . . . . . . . . . . . . . . . . . . 35 D. Install Attic Insulation Shield. . . . . . . . . . . . . . . . . . . . . . . 36 E. Installing the Optional Heat-Zone-Gas Kit . . . . . . . . . . . . 36

9 Appliance Preparation

A. Top Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

B. Rear Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

C. Installing the Non-combustible Board. . . . . . . . . . . . . . . . 39

D. Securing and Leveling the Appliance . . . . . . . . . . . . . . . . 39

10 Installing Vent Pipe (DVP and SLP Pipe)

A. Assemble Vent Sections (DVP Pipe Only) . . . . . . . . . . . . 40 B. Assemble Vent Sections (SLP Pipe Only) . . . . . . . . . . . . 41 C. Assemble Slip Sections . . . . . . . . . . . . . . . . . . . . . . . . . . 41 D. Secure the Vent Sections. . . . . . . . . . . . . . . . . . . . . . . . . 42 E. Disassemble Vent Sections . . . . . . . . . . . . . . . . . . . . . . . 42 F. Install Decorative Ceiling Components (SLP only). . . . . . 43 G. Install Metal Roof Flashing. . . . . . . . . . . . . . . . . . . . . . . . 44 H. Assemble and Install Storm Collar . . . . . . . . . . . . . . . . . . 44 I. Install RF4-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 J. Install Vertical Termination Cap . . . . . . . . . . . . . . . . . . . . 46 K. Install Decorative Wall Components (SLP only). . . . . . . . 46 L. Heat Shield Requirements for Horizontal Termination . . . 46 M. Install Horizontal Termination Cap (DVP and SLP Pipe) . 47

11 Gas Information

A. Fuel Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

B. Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

C. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . 48

12 Electrical Information

A. Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 B. Intellifire Ignition System Wiring . . . . . . . . . . . . . . . . . . . . 49 C. Standing Pilot Ignition System Wiring . . . . . . . . . . . . . . . 49 D. Optional Accessories Requirements . . . . . . . . . . . . . . . . 49 E. Electrical Service and Repair . . . . . . . . . . . . . . . . . . . . . . 50 F. Junction Box Installation. . . . . . . . . . . . . . . . . . . . . . . . . . 51 G. Wall Switch Installation for Fan (Optional) . . . . . . . . . . . . 51

Heat & Glo • 6000G, 6000G-IPI2103-900 Rev. O • 12/08

3

Page 3
Image 3
Hearth and Home Technologies 6000G-IPILP, 6000G-LP owner manual Table of Contents, User Guide

6000G-IPI, 6000G-IPILP, 6000G-LP, 6000G specifications

Hearth and Home Technologies offers an impressive range of gas fireplaces, among which the 6000G series stands out for its innovative design and advanced features. This lineup includes models such as the 6000G, 6000G-LP, 6000G-IPILP, and 6000G-IPI, each providing unique advantages tailored to different preferences and home styles.

The 6000G serves as the cornerstone of this series, featuring a contemporary design that can complement modern and traditional interiors alike. It boasts an expansive viewing area, thanks to its large glass front, allowing for an immersive fire experience while offering impressive heat output. The efficient burner system not only ensures high energy efficiency but also creates a realistic flame profile that enhances the ambiance of any room.

For those looking for versatility in fuel type, the 6000G-LP model offers a liquid propane option, making it suitable for homes that might not have access to natural gas. It maintains the same sleek aesthetic and efficiency as the standard 6000G, ensuring that homeowners can enjoy the sophisticated warmth of a gas fireplace regardless of their fuel preferences.

The 6000G-IPILP model introduces the innovative Ignite Pilot, which allows users to ignite their fireplace with ease using a simple switch. This technology provides the ultimate convenience while enhancing safety, as it eliminates the need for a standing pilot light. Compatible with liquid propane, this model ensures that homeowners can enjoy a hassle-free experience, with efficient operation and maintenance.

Lastly, the 6000G-IPI model features an impressive Intermittent Pilot Ignition system. This system not only enhances efficiency by eliminating unnecessary gas consumption when the fireplace is not in use but also ensures a simple and reliable startup process. With this model, homeowners can take comfort in knowing that their fireplace is designed with both efficiency and user-friendliness in mind.

All models in the 6000G series reflect Hearth and Home Technologies' commitment to quality, performance, and innovation. Each unit is built with durable materials and designed to provide long-lasting beauty and exceptional heating performance. With various sizes and styles available, these fireplaces cater to diverse architectural preferences, making them a perfect addition to any home. Whether opting for the standard 6000G or exploring the advanced functionalities of the LP and IPI models, homeowners can be assured that they are investing in a product that marries functionality with aesthetic appeal.