Isle Royale Wood Stove

D. Chimney Termination Requirements

Follow manufacturer’s instructions for clearance, securing

ashing and terminating the chimney.

Must have an approved and listed cap

Must not be located where it will become plugged by snow or other material

Must terminate at least 3 feet (91cm) above the roof and at least 2 feet (61cm) above any portion of the roof within 10 feet (305cm).

Must be located away from trees or other structures

NOTE:

Chimney performance may vary.

Trees, buildings, roof lines and wind conditions affect performance.

Chimney height may need adjustment if smoking or overdraft occurs.

E. 2-10-3 Rule

These are safety requirements and are not meant to assure proper fl ue draft.

Less than 10 ft. (305cm)

3 ft. (91cm)

Minimum

2 ft. (61cm)

10 ft. (305cm) To Nearest Roofline

2 ft. (61cm)

3 ft. (91cm)

Minimum

Pitched Roof

Figure 18.1

10 ft. (305cm) or more

Wall or Parapet

3 ft. (91cm) Minimum

3 ft. (91cm) Minimum

Less than 10 ft. (305cm)

2 ft. (61cm)Minimum

 

Figure 18.2

Flat Roof

 

 

 

 

 

 

 

 

 

Page 18

250-5763E

November 22, 2011

 

 

Page 18
Image 18
Hearth and Home Technologies 823-0170 - MBK owner manual Chimney Termination Requirements, Rule