R

Isle Royale Wood Stove

10 Troubleshooting Guide

With proper installation, operation, and maintenance your woodstove will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist you or a qualifi ed service person in the diagnosis of a problem and the corrective action to be taken.

Start Fire Problems

Possible Cause

Solution

Can not get fi re started

 

 

Excessive smoke or spillage

Not enough kindling/paper or no

Use dry kindling, more paper. Arrange kindling &

Burns too slowly

kindling/paper

wood for air movement.

Not enough heat output

 

 

 

 

Check for restricted termination cap

 

 

 

 

 

Check for blockage of outside air kit (if installed).

 

 

 

 

 

Check for fl ue blockage.

 

 

 

 

 

Pre-warm fl ue before starting fi re (refer to Building

 

Not enough air for fi re to ignite

a Fire Section).

 

 

 

 

 

Check for adequate vent height (refer to Chimney

 

 

Height Section).

 

 

 

 

 

Open window below the appliance towards the

 

 

wind.

 

 

 

 

Wood condition is too wet, too

Use dry, seasoned wood (refer to Seasoned Wood

 

large

Section).

 

 

 

 

Bed of coals not established

Start with paper & kindling to establish bed of

 

before adding wood

coals (refer to Building a Fire Section).

 

 

 

 

Flue blockage such as birds’

Have chimney inspected for creosote and cleaned

 

nests or leaves in termination

by a certifi ed chimney sweep.

 

cap

 

 

 

 

 

Down draft or negative pressure

Do not use exhaust fans during start-up (refer to

 

Competition with exhaust

Negative Pressure Section).

 

devices

 

 

Open window below the appliance towards the

 

 

 

 

wind.

 

 

 

Fire burns too fast

 

Mix in hardwood.

 

 

 

 

Extremely dry or soft wood

Mix in less seasoned wood after fi re is established

 

 

(refer to Wood Fuel Section).

 

 

 

 

 

Check for correct vent height; too much vertical

 

 

height creates overdrafting.

 

Overdrafting

 

 

Check location of vent termination (refer to

 

 

 

 

Chimney Termination Requirement Section).

 

 

 

November 22, 2011

250-5763E

Page 31

 

 

Page 31
Image 31
Hearth and Home Technologies 823-0170 - MBK owner manual Isle Royale Wood Stove Troubleshooting Guide