Page 25
Isle Royale Wood Stove
R
September 1, 2008 250-5763C
DOOR & GASKET
Periodically check the door gasket for proper seal.
As the gasket compresses or “seats” during use,
it may become necessary to adjust or tighten the
door latch either by removing spacer washers,
shown below (at least one washer must be left
in place) or, by replacing the gasket material as
wear or damage to the gasket material can cause
air leakage into the rebox resulting in overring
and loss of efciency. A replacement gasket is
available from your dealer.
MAINTENANCEEnsure that the rebricks are correctly positioned as referenced by diagram below, and that the
rebox does not contain any broken brick prior to operating the unit.
FIREBRICK REPLACEMENT
9"
3-3/4"
8-1/4"
1-1/16"
4-1/2"
3
Use Part 832-0550 when ordering individual brick. Please provide brick dimensions or copy this page and
mark the desired brick and take it to your authorized dealer.
Locknut
Door Cross Section
(example)
Latch Cam
Spacing Washers
Square Key
Handle
Teflon Washer
DO NOT REMOVE
1
1
22
3
33
3
44
55
4-1/2"
9"
5"