Page 9
Isle Royale Wood Stove
R
September 1, 2008 250-5763C
REVERSIBLE FLUE COLLAR
The ue collar is reversible for either a top or rear venting
installation. The unit is shipped with the ue collar in the top
vent position.
CONVERTING COLLAR FOR REAR VENT INSTALLATION
1. Remove 5 Phillips head screws from the rear shield, lift
shield up and set aside.
2. Remove bolts from each side of the ue transition (2
total). (Place your free hand in ue opening to locate
and retrieve nuts attached to bolts.)
3. Turn vent to horizontal position. Inspect sealant to ensure
a leak free application.
4. Re-assemble in reverse order.
Mounting Screws
Bend Flange Down
Please note this cover plate will not
work with the Low-Prole Kit
REAR FLUE DEFLECTOR COVER PLATE
This cover plate is used when the ue collar is turned for a
rear vent application.
2. Bend the cover plate ange down.
3. Secure the cover plate with the remaining two screws.
1. After the ue collar has been reversed for a rear vent
installation, install the cover plate on the stove with the
two screws provided.