3100-I ACT WOOD INSERT

CLEARANCES TO COMBUSTIBLES

United States and Canada

R

 

Maximum Mantel Depth - 10" (254mm)

 

 

Mantel

 

SideWall

B

Fascia or Trim

 

C

 

 

A

 

 

Insert

D

 

 

 

 

 

 

F

E

 

Hearth Extension

*Zero Clearance Installations USA Only

In Canada a full length 6” (152mm) S635 flue liner required as per ULC S628.

NOTE: When installing into a masonry fire- place, the fireplace must be built to UBC Chapter 37 standards. Do not remove brick or mortar from masonry fireplace to accom- modate insert. The permanent metal warn- ing plate provided must be attached to the back of the fireplace stating the fireplace may have been altered to accommodate the insert and must be returned to original con- dition for use as a conventional fireplace.

 

USA

CANADA

A

Sidewall to Stove

16"

16" (406mm)

B

Mantel Clearances

 

 

 

*No Mantel Shield

33"

34" (864mm)

 

with 5" Mantel Deflector

27"

24" (610mm)

 

with 8" Mantel Deflector

17"

16"(406mm)

 

with Mantel Shield Only

24"

18"(457mm)

 

5" Deflector & Mantel Shield

23"

15"(381mm)

 

8" Deflector & Mantel Shield

15"

15"(381mm)

C

Top Trim to Stove

 

 

 

*No Mantel Shield

30"

30" (762mm)

 

with 5" Mantel Deflector

23"

21" (533mm)

 

with 8" Mantel Deflector

16"

14"(356mm)

 

with Mantel Shield Only

22"

14"(356mm)

 

5" Deflector & Mantel Shield

15"

14"(356mm)

 

8" Deflector & Mantel Shield

12"

14"(356mm)

D

Side Trim to Stove

6"

6" (152mm)

E Hearth Extension-Front

 

 

 

Floor height 0" to 8" below Insert

18"

18" (457mm)

 

Floor height greater than 8"

16"

18"(457mm)

F

Hearth Extension-Side

8"

8" (203mm)

 

 

 

 

Thermal Protection USA & Canada

Thermal protection must be ('k" value = 0.84) or equivalent material*

Floor height 0" to 8" below Insert

1 Inch (12.7mm) of "k" = 0.84

Floor height greater than 8"

1/2 inch (25mm) of "k" = 0.84

*See Alternative Floor Protection Worksheet on page 7.

The Mantel Shield must be comprised of a non-combustible mate- rial located a minimum of 1” (25mm) from mantel’s under side extending to the full width of the mantel. The Mantel Deflector’s are available from your dealer.

 

 

 

 

September 1, 2008

250-638D

Page

Page 5
Image 5
Hearth and Home Technologies 3100-I, 830-0381 owner manual ACT Wood Insert Clearances to Combustibles