![](/images/new-backgrounds/1027842/2784269x1.webp)
R
Castile Pellet Stove
|
| Reference Materials |
|
|
| ||
|
|
|
|
|
|
| |
|
|
|
|
|
| ||
Component Function |
| When describing the location of a component, |
| ||||
|
|
| |||||
|
| it is always AS YOU FACE THE FRONT OF |
| ||||
A.11 |
|
|
|
| |||
1. Control Box |
|
|
| THE APPLIANCE. |
| ||
a. The control box is located on upper right side of |
|
|
| ||||
7. Heat Exchangers | |||||||
appliance, behind the right side panel and above the | |||||||
vacuum switch. |
|
| The heat exchangers transfer hot air from the exhaust system | ||||
b. There is a light located inside of the control box. The | into convecton air. Remove the stainless steel top baffle to | ||||||
internal light will turn green when the appliance has | access the heat exchangers. There are 2 clean out rods | ||||||
reached a temperature of 175οF (79°C) in the firepot. | located under the heat exchangers. | ||||||
and will turn red when it reaches 600oF (315°C). | 8. Heat Output Switch | ||||||
|
|
|
|
c. There is also an internal blue light located in the upper
The heat output switch is located on the upper right rear
left corner of the control box. When you plug in the
corner. The funtion of the heat ouput switch is to regulate
appliance the blue light will automatically start blinking
4 times in a row for 60 seconds and then will stop.
the burn rates; low, medium and high settings.
NOTE:
Do NOT open the control box. This will void the warranty. FolIow proper shutdown procedures first if you need to plug in or remove the control box.
2.Convection Blower
The convection blower is mounted at the bottom rear of the appliance. There are 2 impellers, one on each side of the motor. The convection blower pushes heated air through the heat exchange system into the room.
3.Combustion Blower
The combustion blower is located on the right side of appliance and is designed to pull the exhaust from the appliance and push it out through the venting system.
4.Feed System
The feed system is located on the right side of the appliance and can be removed as an entire assembly. The assembly includes the feed motor, mounting bracket, bearing and feed spring (auger). The hollow feed spring (auger) pulls pellets up the feed tube from the hopper area and drops them down the feed chute into the firepot.
5.Firepot
9.Igniter
The igniter is mounted on the base of the firepot. Combustion air travels over the red hot igniter creating super heated air that ignites the pellets.
10.Junction Box And Wiring Harness
The junction box is located on the right side of the appliance, behind the right side panel. The junction box and wiring harness are replaced as one component.
11.Power Supply
The power outlet is located on the lower right rear corner. Check the wall receptacle for 120 volt, 60 Hz (standard current). Make sure the outlet is grounded and has the correct polarity. A good surge protector is recommended.
12.Red Call Light
The red call light is on the front of the junction box, behind the control box. The function of the red call light is to indicate that the thermostat is calling for heat.
13.Reset Button
The reset button is located on the back of the appliance on the upper right corner of the side panel under the heat output control switch. The function of the button is to momentarily open the thermostat circuit, which restarts the system.
14.Thermocouple
The firepot is made of high quality ductile iron and has a cleaning
6.Fuse
The thermocouple is located on top of the firepot inside the thermocouple cover (ceramic protection tube). The thermocouple sends a millivolt signal to the control box indicating the preset temperatures of the green and red lights have been obtained.
15.Thermostat
The fuse is located on the front of the junction box on the right side of appliance. The fuse will blow should a short occur and shut off power to the appliance.
The appliance is designed to run on a 12 volt AC thermostat. The heat anticipator should be set on the lowest setting available.
September 1, 2008 | Page 35 |