C. Hearth Pad Requirements (UL and ULC)

Use a non-combustible floor protector, extending beneath appliance and to the front, sides and rear as indicated. Measure front distance “M” from the surface of the glass door.

 

L*

 

 

K

K

 

 

M

 

 

Hearth Pad Requirements

Inches

Millimeters

K

Sides

2

51

L*

Back

2

51

M

Front

6

152

*L Exception for Horizontal Installations:

USA INSTALLATIONS: A non-combustible floor protection is recommended extending beneath the flue pipe when installed with horizontal venting or under the Top Vent Adapter with vertical installation.

CANADA INSTALLATIONS: A non-combustible floor pro- tection extending beneath the flue pipe is required with hori- zontal venting or under the Top Vent Adapter with vertical installation.

Must extend 2 inches (51mm) beyond each

side of pipe (shaded area)