TS345/TS345P Square Termination Cap

Collar

2 in. (51 mm)

Minimum Height

Chase Top

Place waterproof sealer under each flange of the termination cap and on top of each screw to help prevent leaks.

Termination Cap

The last section of pipe must stop between 2 in. (51 mm) above the top of the chase and 4 3/4 in. (121 mm) below the top of the chase.

2 in. (51 mm)

maximum

4 3/4 in. (121 mm)

maximum

Chase

Chimney

Pipe

Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm).

Figure 9.7 Installing a TS345/TS345P Square Termination Cap

TCT375 Terra Cotta Cap

 

Place waterproof sealer

Remove 2 screws

under each flange of the

termination cap and on

from front & back

top of each screw to

to lift the top off

help prevent leaks.

 

Termination Cap

The last section of pipe

 

must stop between 2 in.

 

(51 mm) above top of

Collar

chase and 7 in. (178 mm)

below top of chase

2 in. (51 mm)

 

Minimum Height

 

Chase Top

2 in. (51 mm)

 

7 in. (178 mm)

Chase

Chimney

Pipe

Termination cap pipe and chimney section must overlap

1-1/2 in. (38 mm)

Figure 9.8 Installing a TCT375 Terra Cotta Cap

Heatilator • EL36/EL42 • 4044-132 • Rev AD• 7/12

35

Page 35
Image 35
Hearth and Home Technologies EL42, EL36 owner manual TS345/TS345P Square Termination Cap