6Framing & Clearances

A. Select Fireplace Location

G

F

A Across a

C corner

E

H

As a room divider

A

B

In an exterior chase or projecting into a garage

H

I

Note: 1/2 in. (13 mm) min. air space from fireplace to combustible materials.

Note: In addition to these framing dimensions, also reference the following sections:

Clearances (Section 6.B.)

Mantel Projections (Section 11.E.)

Fireplace Dimensions (Section 13.A.)

D A

48 in.

(1219 mm)

minimum

Along a wall

B

A

I

H

5/8 in. (16 mm) all configurations

Note: Measurements are FRAMING dimensions only and do not include drywall either in the cavity or on the interior walls.

Model

 

A

B

C

D

E

F

G

H

I

EL36

inches

42

50

67 7/8

59 1/2

34

14

48

21 1/2

12 in. (305 mm)

mm

1067

1270

1724

1511

864

356

1219

546

Minimum from FP

 

EL42

inches

48

56

73 7/8

65 1/2

37 1/4

14

52 1/4

21 1/2

opening to any

mm

1219

1422

1876

1664

946

356

1327

546

perpendicular wall.

 

Figure 6.1 Fireplace Locations (Framing dimensions shown)

18

Heatilator • EL36/EL42 • 4044-132 • Rev AD • 7/12

Page 18
Image 18
Hearth and Home Technologies EL36, EL42 owner manual Framing & Clearances, Select Fireplace Location