D. Install Termination Cap

Install the chimney sections up through the chase enclo- sure.

Refer to termination cap instructions.

WARNING! Risk of Fire! The minimum overlap of cap to pipe (as shown in the following illustrations) MUST be met or chimney may separate from cap. Separation allows sparks, heat and embers to escape.

NOTICE: Paint the termination cap with a rust-resistant paint to protect against the effects of corrosion on those parts exposed to the weather.

TR11 Round Termination Cap

TR11T Round Telescoping Termination Cap

Assemble

Termination

storm collar

Cap

around extended

 

 

 

 

 

termination cap

 

 

 

 

 

pipe

 

 

 

 

 

once cap is

 

 

 

 

 

installed.

 

 

 

Do NOT

 

 

 

 

 

 

 

 

block air

 

 

 

 

Caulk gaps between

 

 

 

holes

storm collar & pipe,

Storm

and storm collar

Collar

& chase top.

 

 

 

3 clip brackets.

 

 

 

Slip over chase collar

 

 

 

and attach with screws

 

 

 

 

provided.

Collar

 

 

 

 

 

2 in. (51 mm)

 

 

14 1/2 in. (368 mm)

Minimum Height

 

 

 

 

 

Maximum

 

 

 

 

 

Termination

Cap

Slip

storm collar

around chimney pipe

before termination cap pipe is snapped into the chimney pipe.

Caulk gaps between

Storm

storm collar & pipe,

Collar

and storm collar

 

& chase top.

 

Collar

 

2 in. (51 mm)

Chimney

Minimum Height

Pipe

 

Chase Top

 

Do NOT

block air holes

6 in. (153 mm) Minimum top of chase to top of chimney pipe

Chase Top

Chase

Chimney

Pipe

Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)

Figure 9.5 Installing a TR11T Round Telescoping Termination Cap

ST1175 Square Termination Cap

Chase

Termination cap pipe and chimney section must be snapped together to maintain an overlap of 1-1/2 in. (38 mm).

Figure 9.4 Installing a TR11 Round Termination Cap

Termination Cap

Collar

2 in. (51 mm)

Minimum Height

Chase Top

Chimney

Pipe

Place waterproof caulk or sealer under each flange of the termination cap and on top of each screw to help prevent leaks.

Flange

4 3/4 in. (121 mm)

Maximum

top of chase to top of

chimney section

Chase

Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)

Figure 9.6 Installing an ST1175 Square Termination Cap

34

Heatilator • Multi-Sided Woodburning Fireplace • 34955 • Rev V • 11/08

Page 34
Image 34
Hearth and Home Technologies FL92 owner manual Install Termination Cap, ST1175 Square Termination Cap

FL92 specifications

Hearth and Home Technologies (HHT) has long been recognized as a leader in the hearth industry, providing innovative and efficient heating solutions. Among its impressive lineup, the FL92 stands out as a versatile and modern gas fireplace that enhances both ambiance and functionality in various living spaces.

One of the main features of the FL92 is its expansive viewing area. The large glass front offers an unobstructed view of the flames, creating a mesmerizing focal point for any room. It allows consumers to enjoy the warmth and beauty of a traditional fire without the hassle of wood or ash cleanup. The design effectively blends contemporary aesthetics with practicality, making it an appealing choice for modern homes.

In terms of technology, the FL92 is equipped with advanced heating capabilities. It utilizes a powerful yet efficient burner system that provides reliable heat output while maximizing fuel efficiency. This means homeowners can enjoy a cozy atmosphere on chilly evenings while being mindful of energy consumption, potentially leading to lower utility bills.

Additionally, the FL92 features a variety of customizable options to suit individual preferences and home décor. Customers can choose from different finishes, media options, and decorative fronts to create a personalized look that complements their interior design. This level of customization ensures that the FL92 can be seamlessly integrated into any space, whether it’s a contemporary loft or a traditional living room.

Another standout characteristic of the FL92 is its easy installation and user-friendly operation. HHT has designed the unit with the homeowner in mind, making it compatible with a variety of installation scenarios, including zero-clearance applications. This versatility simplifies the process for contractors and homeowners alike.

Safety is also a top priority for HHT, and the FL92 is designed with several safety features, including an automatic shut-off function and a tempered glass front that remains cool to the touch. These elements not only provide peace of mind but also contribute to the overall user-friendly experience.

In conclusion, the Hearth and Home Technologies FL92 is a modern gas fireplace that combines aesthetic appeal with advanced heating technology and safety features. Its spacious viewing area, customizable options, and efficient operation make it an excellent choice for those looking to enhance their living spaces with the warmth and ambiance of a sophisticated fireplace. Whether for new builds or renovation projects, the FL92 stands out as a reliable and stylish option in the world of home heating solutions.