GFK-210-C Blower System

GFK-210-C Blower System

- Installation and Operating Instructions -

1.0 INTRODUCTION

The GFK-210-C Blower System has been designed to circulate room air through the fireplace to enhance heat output. The GFK-210-C blower system operates on 120 VAC, 60 Hz power. This is available through a receptacle in the factory installed power cord assembly. The power cord is located in the controls compartment of the fireplace.

An optional variable speed control is available for use with the blower system to provide quiet forced air flow at the desired speeds. A temperature sensor switch, which automatically turns the blower ON/OFF, is also provided with this kit. See Figure 2 and Section 8.0.

NOTICE: The variable speed control and temperature sensor switch are not used with some remote control systems.

2.0 CHECK CONTENTS OF SHIPPING CARTON

Compare CONTENTS OF CARTON in Figure 1 with the actual parts received. If any parts are missing or damaged, contact your dealer before starting installation.

3.0 INSTALLATION PRECAUTIONS

The GFK-210-C Blower Kit is tested and safe when installed in accordance with this installation manual. It is your respon- sibility to read all instructions before starting installation and to follow these instructions carefully during installation to assure maximum benefit from, and safe operation of, the blower.

This blower is carefully engineered and must be installed only as specified. If you modify it or any of its components, you may cause a fire hazard and will void the WARRANTY. In addition, such action may void the coverage provided by the owner's home insurance.

CAUTION! Do not install a damaged blower kit.

BLOWER CORD

FAN

BRACKETS

Figure 1. Carton Contents - GFK-210-C

CAUTION: All wiring should be done by a qualified electri- cian and shall be in compliance with local codes and with the National Electric Code ANSI/NFPA NO. 70-current (in the United States), or with the current CSA C22.1 Canadian Electric Code (in Canada).

CAUTION! DO NOT connect 110-120 VAC wiring to the

gas control valve of the fireplace.

WARNING! Risk of Shock! Turn electrical power off at the circuit breaker before beginning this installation.

OPTIONAL

WING

RHEOSTAT/TEMPERATURE

NUT

SENSOR ASSEMBLY

 

TEMPERATURE

 

SENSOR

 

SWITCH

 

CONTROL

 

NUT

 

CONTROL

 

KNOB

 

VARIABLE SPEED CONTROL

Figure 2. Carton Contents - SRV2206-800

 

Hearth & Home Technologies • GFK-210-C Blower System Instructions 2201-938 Rev. E • 9/12