•Dexen Valve (IPI)
-Connect the black, white and red wires with 1/4 in. female connectors from fan control module to appliance junction box as shown in Figure 10.
-Connect the black ground wire to the appliance.
-Remove the green ignition control wire from the valve.
-Connect the black with white stripe wire with 3/16 in. piggyback connector from fan control module to valve.
-Connect green ignition control wire to piggyback connector on black with white stripe fan control module wire.
Dexen | Wire from Ignition Control |
|
Green |
| |
Valve |
| |
Black/White |
| |
| White | |
Fan |
| |
Black |
| |
Control | Red | |
| Module | |
|
| |
Ground |
| Black |
|
| |
Figure 10 - Dexen (IPI) Wiring Diagram |
|
•SIT Valve
-Connect the black, white and red wires with 1/4 in. female connectors from fan control module to appliance junction box as shown in Figure 11.
-Connect the black ground wire with the ring terminal to the TP screw on the valve (center).
-Connect blue jumper wire between fan control wire (black with white stripe) and valve. Plug 1/4 in. female end of blue jumper wire to the back side of valve wiring block marked TH.
Thermopile
Wall
Switch
SIT | TH | |
TP | ||
Valve | ||
TH TP | ||
| ||
Ground | Black/White | |
| Black |
te Whi
Red | Blue |
|
Fan
Control
Module
White
Red
Black
Figure 11 - SIT Wiring Diagram
6. Recommended Fan Control Set-up Procedure
Note: The test sequence works only during the first (approximately) seven minutes after
•With burner and pilot extinguished:
•Turn control knob clockwise to activate control.
•Press and hold test button on the control module.
-Fan will turn on.
-Adjust fan speed with control knob.
-Release test button. Fan will stop.
•Light burner.
•Press and release test button.
-Fan will come on at set speed
-After one minute fan will stop.
•Extinguish burner.
•Fan control is now fully operational and will operate automatically each time appliance is used.
•Operates with APPROXIMATELY a