B. Design and Installation Considerations

NOTICE: Check building codes prior to installation.

Installation MUST comply with local, regional, state and national codes and regulations.

Consult insurance carrier, local building inspector, fire officials or authorities having jurisdiction over restrictions, installation inspection and permits.

Before installing, determine the following:

Where the fireplace is to be installed

The vent system configuration to be used

Gas supply piping

Electrical wiring

Framing and finishing details

Whether optional accessories—devices such as a fan, wall switch or remote control—are desired

NOTICE: Junction box should be installed during initial setup to avoid major reconstruction.

C. Draft

Draft is the pressure difference needed to vent fireplaces successfully. When a fireplace is drafting successfully, all combustion byproducts are exiting the home through the chimney.

Considerations for successful draft include:

Preventing negative pressure

Location of fireplace and chimney

NOTICE: Hearth & Home Technologies assumes no responsibility for the improper performance of the fireplace system caused by:

Inadequate draft due to environmental conditions

Downdrafts

Tight sealing construction of the structure

Mechanical exhausting devices

Improper location of the chimney

D. Negative Pressure

WARNING! Risk of Asphyxiation! Negative pressure can cause spillage of combustion fumes and soot. Fire must draft properly for safe operation.

Negative pressure results from the imbalance of air avail- able for the fireplace to operate properly. It can be stron- gest in lower levels of the house.

Causes include:

Exhaust fans (kitchen, bath, etc.)

Range hoods

Combustion air requirements for furnaces, water heaters and other combustion appliances

Clothes dryers

Location of return-air vents to furnace or air conditioning

Imbalances of the HVAC air handling system

Upper level air leaks such as:

-Recessed lighting

-Attic hatch

-Duct leaks

To minimize the effects of negative air pressure:

Install the outside air kit with the intake facing prevailing winds during the heating season

Ensure adequate outdoor air for all combustion appliances and exhaust equipment

Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the fireplace

Avoid installing the fireplace near doors, walkways or small isolated spaces

Recessed lighting should be a “sealed can” design

Attic hatches weather stripped or sealed

Attic mounted duct work and air handler joints and seams taped or sealed

Basement installations should be avoided

NOTICE: Hearth & Home Technologies Inc. recommends the use of direct vent fireplaces in basements.

Heatilator • I60, I80 • 4013-250 • Rev C • 11/08

15

Page 15
Image 15
Hearth and Home Technologies I80, I60 owner manual Design and Installation Considerations, Draft, Negative Pressure

I80, I60 specifications

Hearth and Home Technologies’ I60 and I80 are highly regarded as premier options in the realm of direct vent gas fireplaces. Both models are designed to provide elegant aesthetics and outstanding performance, making them ideal for any living space. The I60 features a 60,000 BTU input, while the I80 boasts a higher input of 80,000 BTUs, ensuring ample warmth and comfort. These fireplaces are well-suited for large rooms and homes with open floor plans, delivering significant efficiency alongside superior design.

One of the standout features of both the I60 and I80 models is their contemporary style. The large glass viewing area creates a stunning visual impact, allowing the flames to be the focal point of the room. The clean, linear design can be customized to fit various décor styles, making it versatile for homeowners. Additionally, the fireplaces can come with optional decorative media such as ceramic logs, stones, or glass, allowing for further personalization.

Both fireplaces incorporate advanced technologies to enhance performance and efficiency. The inclusion of the IntelliFire® ignition system offers a reliable and convenient way to start the fireplace, eliminating the need for messy matches or lighters. The remote control functionality adds convenience, allowing users to adjust flame height and heat output from anywhere in the room.

Efficiency is another key characteristic of the I60 and I80. They boast high-efficiency ratings, contributing to lower energy bills while providing superior warmth. The direct vent technology ensures that combustion gases are expelled outside, preventing indoor air pollution and allowing for excellent airflow.

Installation is also simplified with these models due to their flexible venting options. They can accommodate various venting configurations, including horizontal and vertical installations, which is particularly beneficial in both new construction and retrofit applications. The fireplaces come equipped with safety features such as a standard safety screen and optional glass doors, ensuring peace of mind for users.

In summary, Hearth and Home Technologies’ I60 and I80 gas fireplaces offer an exceptional combination of style, efficiency, and advanced features. With their contemporary design, customizable media options, reliable ignition system, and high efficiency, they stand out as reliable heating solutions for modern homes. Whether for comfortable warmth or creating an inviting ambience, these models are sure to enhance any living space.