Hearth and Home Technologies I80, I60 owner manual Install Attic Insulation Shield, 330 mm

Models: I80 I60

1 56
Download 56 pages 47.07 Kb
Page 31
Image 31

F. Install Attic Insulation Shield

WARNING! Risk of Fire! You MUST install an attic insu- lation shield when there is any possibility of insulation or other combustible material coming into contact with the chimney.

DO NOT pack insulation between the chimney and the attic insulation shield.

Failure to keep insulation and other materials away from chimney pipe could cause fire.

DO NOT offset chimney inside insulation shield.

Installation of a ceiling firestop is required

Refer to Figures 8.6 - 8.8.

Roll the shield (around the chimney if already installed) until you have a 3 in. (76 mm) overlap and the three holes on each side match up (large holes on top).

Insert three screws into the matching holes to form a tube.

Bend three tabs on the bottom of the tube inward to 90° to maintain chimney air space (refer to Figure 8.6).

Rest the insulation shield on the ceiling firestop below.

Bend the three short tabs at the top of the shield inward to 90° to maintain the 2 in. (51 mm) air space from the chimney.

Bend the remaining top tabs to just meet the pipe.

If you wish to make a custom shield or barrier, follow these guidelines:

Metal is preferred, although any material stiff enough to hold back the insulation can be used.

WARNING! Risk of Fire! Use of cardboard or other materials that can deflect under humidity or other envi- ronmental conditions is not recommended.

The shield or barrier must be tall enough to extend above the insulation and prevent blown-in insulation from spilling into the cavity.

Maintain specified air spaces around chimney.

Check instructions and local codes for further details.

 

 

 

 

Bend remaining tabs

 

 

 

 

to rest against pipe to

Bend

 

inward

prevent insulation

90°

 

from falling in.

 

 

 

 

 

Insert three

 

 

 

 

screws

3 in. (76 mm) overlap

Figure 8.6 Prepare Attic Insulation Shield

 

 

Tabs bent in to

 

Pipe

rest against pipe

 

 

 

 

Attic Insulation Shield

 

 

17 in. (432 mm)

 

6 Tabs bent

diameter

 

in 90°

Ceiling Firestop

 

 

Insulation

Pipe

Insulation

13 in.

(330 mm)

Figure 8.7 Install Attic Insulation Shield (firestop above ceiling)

 

 

Tabs bent in to

 

 

rest against pipe

 

Pipe

 

 

 

Attic Insulation Shield

 

 

17 in. (432 mm)

 

 

diameter

 

6 Tabs bent

 

 

in 90°

 

Insulation

 

Insulation

13 in.

Pipe

Ceiling Firestop

(330 mm)

 

 

Figure 8.8 Install Attic Insulation Shield (firestop below ceiling)

Heatilator • I60, I80 • 4013-250 • Rev C • 11/08

31

Page 31
Image 31
Hearth and Home Technologies I80, I60 owner manual Install Attic Insulation Shield, 330 mm

I80, I60 specifications

Hearth and Home Technologies’ I60 and I80 are highly regarded as premier options in the realm of direct vent gas fireplaces. Both models are designed to provide elegant aesthetics and outstanding performance, making them ideal for any living space. The I60 features a 60,000 BTU input, while the I80 boasts a higher input of 80,000 BTUs, ensuring ample warmth and comfort. These fireplaces are well-suited for large rooms and homes with open floor plans, delivering significant efficiency alongside superior design.

One of the standout features of both the I60 and I80 models is their contemporary style. The large glass viewing area creates a stunning visual impact, allowing the flames to be the focal point of the room. The clean, linear design can be customized to fit various décor styles, making it versatile for homeowners. Additionally, the fireplaces can come with optional decorative media such as ceramic logs, stones, or glass, allowing for further personalization.

Both fireplaces incorporate advanced technologies to enhance performance and efficiency. The inclusion of the IntelliFire® ignition system offers a reliable and convenient way to start the fireplace, eliminating the need for messy matches or lighters. The remote control functionality adds convenience, allowing users to adjust flame height and heat output from anywhere in the room.

Efficiency is another key characteristic of the I60 and I80. They boast high-efficiency ratings, contributing to lower energy bills while providing superior warmth. The direct vent technology ensures that combustion gases are expelled outside, preventing indoor air pollution and allowing for excellent airflow.

Installation is also simplified with these models due to their flexible venting options. They can accommodate various venting configurations, including horizontal and vertical installations, which is particularly beneficial in both new construction and retrofit applications. The fireplaces come equipped with safety features such as a standard safety screen and optional glass doors, ensuring peace of mind for users.

In summary, Hearth and Home Technologies’ I60 and I80 gas fireplaces offer an exceptional combination of style, efficiency, and advanced features. With their contemporary design, customizable media options, reliable ignition system, and high efficiency, they stand out as reliable heating solutions for modern homes. Whether for comfortable warmth or creating an inviting ambience, these models are sure to enhance any living space.