Page 16 7036-135E September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
C. Full Reline With Outside Air
Figure 16.1
OutsideAir
Termination
at
himne Top
OutsideAir
through
Rear Wall
in mm
min below
in mm
min above
NOT se metal
plate around
exhaust vent pipe
and seal all edges
with non-flammable
insulation such as
fiberglass mineral
wool or ceramic
o not use high
temperature caulk-
ing materials to
seal an edge to
prevent future
serviceabilit

NOTE: Check clearances carefully for this type of instal-

lation to ensure adequate room for outside air venting.

Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Consult local building, fire officials or authorities having
jurisdiction about restrictions, installation inspection, and
permits.
CAUTION

NOTE: In Canada only a full reline is allowed per ULC

S628, ORD ULC C1482-M1990.