Page 10 7036-135E September 1, 2008
R
Mt. Vernon Pellet Insert (AE)
E. Minimum Opening for Masonry and Zero Clearance Fireplaces
Location Inches Millimeters
A Insert side to combustible side wall 6 152
B Insert top to max. 2-1/4 inch face trim 0 0
C
Insert side to max. 2-1/4 inch face trim
00
Location Inches Millimeters
F Rear Width 24 610
G Depth 15 381
H Height 23-7/8 606
I Front Width 34 864
Figure 10.2
Figure 10.3
C. Masonry and Zero Clearance Fireplaces
Location Inches Millimeters
D Floor protection hearth extension from
door opening 6 152
E Floor protection to the side of door
opening
6 152
D. Floor Protection
F
GH
I
F. Mantel ProjectionsJK
Mantel Face
Trim
D
E
AC
B
SideWall
Figure 10.4
Built-In Vertical
Figure 10.1
se two degree elbows to
clear heat shield and hopper
in
mm
in
mm
in
mm
The maximum mantel depth (J) is 12 inches (305mm) with
a minimum vertical height (K) of 12 inches (305mm).
However if your mantel has a depth of 10 inches (254mm)
then the vertical minimum height is 10 inches (254mm).