R
September 1, 2008 7036-135E Page 9
Mt. Vernon Pellet Insert (AE)
Fire Risk.
Comply with all minimum
clearances to combustibles as
specified.
WARNING
Failure to comply may cause
house fire.
NOTE:
Illustrations reflect typical installations
and are FOR DESIGN PURPOSES
ONLY.
I
llustrations/diagrams are not drawn to
scale.
Actual installation may vary due to
individual design preference.
ACBDCB

0 inch Clearance To Exposed Section And FaceTrim

E

B. Clearance To Combustibles, UL and ULC

Location Configuration Inches Millimeters
A Top of Hopper Top or Rent Vent 3 76
B Side of Outside Skin Top or Rear Vent 2 51
C Back of Hopper Top Vent 7-1/2 191
Rear Vent 2-3/4 70
D Vent Pipe to Combustible Top or Rear Vent 3 76
E Cast Side to Side Wall Top or Rear Vent 6 152

Outside Air

Top/RearVent
3 in. (76mm)
Back of Hopper
2.75 in. (70mm)
6 in
(152mm)

Built-in Unit - Rear Vent with Outside Air

Figure 9.1
Figure 9.2

Built-in Unit - Rear Vent