Cisco Systems ACIP-SM(=) manual Examples of ATM Error Messages

Models: ACIP-SM(=)

1 32
Download 32 pages 807 b
Page 28
Image 28
Examples of ATM Error Messages

Examples of ATM Error Messages

To display ATM events, use the debug atm events command:

This command displays event changes to the ACIP. Reset, VC configurations, ACIP configurations, and PLIM failures are displayed.

After you use a debug command, turn off debugging with the no debug command.

Following are additional debug commands specifically related to the ACIP:

To display changes in connectivity to the TeraLink system, use the debug cable channel command.

To display changes in subscriber modem status, use the debug cable modem command.

To display error messages that are caused by unexpected system behavior or problems connecting to the Teralink system, use the debug cable error command.

Examples of ATM Error Messages

Following is a list of possible error messages displayed when you enter the debug atm event command:

Error Message

RESET(ATM2/0): PLIM type is 0, Rate is 0Mbps

Explanation Displays the PLIM TYPE value returned from the ACIP and the expected associated rate.

Error Message

AIP_disable(ATM2/0): state=1

Explanation The DISABLE code to shut the ACIP down has been entered.

Error Message

config(ATM2/0)

Explanation The current configuration to the ACIP was sent including TXBUFF, RXBUFF, exception queue length, raw queue length, and rate queue information.

Error Message

AIP_enable(ATM2/0)

Explanation The ACIP is taken out of shutdown.

28ATM Cable Interface Processor (ACIP) Installation and Configuration

Page 28
Image 28
Cisco Systems ACIP-SM(=) manual Examples of ATM Error Messages