INSTALLATION INSTRUCTIONS
Installing Electrical Service to the Junction Box
WARNING: TURN ELECTRICAL POWER OFF AT THE CIRCUIT BREAKER BEFORE BEGINNING THIS INSTALLATION.
NOTE: Some appliances do not have a cover plate. Instead, there is a hole through which the Romex clamp is attached to the outer wrap.
1.Remove the electrical cover plate from the lower side of the fireplace. Remove the
ACCESS HOLE |
110 VAC |
SERVICE |
COVER |
PLATE |
Figure 1 |
2.Feed the electrical service wires through the Romex clamp and secure the wires to the clamp.
3.Using the wire nuts provided, connect the service wires to the junction box. The black wires to the black service wire, the white wires to the white service wire, and the service ground wire to the ground stud of the junction box.
4.
WARNING: LEAVE ELECTRICAL POWER OFF AT THIS TIME. DO NOT RESTORE POWER UN- TIL THE REMOTE CONTROL SYSTEM IS COM- PLETELY INSTALLED.
REMOTE RECEIVER
Important: The remote receiver should be positioned close to front in right or left corner where ambient temperatures do not exceed 170º F.
The remote receiver is powered by
Locating Receiver and Operating Functions
This remote receiver can be positioned under the firebox in the control compartment of the fireplace if ambient temperatures do not exceed 170º F. This system is de- signed to control the following components:
|
| Wire Colors |
• | Gas Valve - Millivolt or |
|
| Electronic Ignition | Red |
• Fan/Blower - 110 VAC | Plug from Fan | |
• | Flame Controller - HI/LO solenoid | Orange |
RECEIVER WIRING INSTRUCTIONS
Incorrect wiring connections WILL cause damage to the gas valve or electronic module operating the gas appli- ance and may also damage the remote receiver.
Wiring Flame Function (Standing Pilot, DSI, IPI)
Connect the remote receiver by connecting the two red wires leading from the remote receiver to the red and brown remote wires labeled “FOR USE WITH REMOTE OR WALL SWITCH ONLY”. See Figure 2.
|
|
| REMOTE |
|
|
|
| RECEIVER |
|
|
| RED |
| VALVE |
|
|
| TH | |
ON/OFF |
|
|
| |
SWITCH | REMOTE SWITCH |
| RED | |
|
| |||
| PIGTAIL |
| TP | |
|
|
| ||
| RED |
|
| TP TH |
|
|
|
| |
| BROWN |
|
|
|
Figure 2. | WALL |
|
|
|
SWITCH |
|
|
|
Alternative Wiring for units with a wall switch
Disconnect the wall switch wire from the TH terminal on the valve and connect this wire to male connector sup- plied on the receiver. Connect remaining female connec- tor from receiver to the TH terminal on the valve.
Adding Optional Fan/Blower
Plug
(Receptacle on back)
LEARN110/120 VAC, 3A
REMOTE |
|
|
|
| |
RECEIVER | Line cord | |
| from fan |
Figure 3. Adding Fan/Blower
2