CAUTION

Handle glass assembly with care.

When cleaning glass door:

Avoid striking, scratching or slamming glass.

Do NOT use abrasive cleaners.

Use a hard water deposit glass cleaner on white film.

Do NOT clean glass when it is hot.

WARNING

Fire Risk

Do not use chimney cleaners or flame colorants in your fireplace.

Will corrode chimney.

WARNING

Asphyxiation Risk

Fire Risk

Annual inspection by qualified technician recommended.

Check:

Condition of doors, surrounds and fronts

Condition of glass and glass assembly

Obstructions of combustion and ventilation air

Gas connections and fittings (if present)

Obstructions of termination cap

Refractory panels

Clean:

Glass

Air passageways, grilles

D. Maintenance Task List

Inspect

 

Maintenance Tasks

Screens

1.

Assess condition of screen and replace as necessary. Screens are required.

 

 

 

 

2.

Verify maintenance of proper clearance to combustible household objects.

 

 

 

Glass Doors

1.

Inspect glass panels for cracks. Replace if this condition is present.

 

 

 

 

2.

Confirm there is no damage to glass or glass frame. Replace as necessary.

 

 

 

 

3.

Clean glass using a non-abrasive cleaner such as Brasso©.

 

 

 

Circulation Compartment

1.

Remove any foreign objects.

 

 

 

 

2.

Verify unobstructed air circulation.

 

 

 

Firebox

1.

Inspect condition of refractory. Replace if crumbly, deteriorated, or if cracks exceed 1/4 in. (6 mm).

 

 

 

Chimney

1.

Inspect for blockage or obstruction such as bird nests, leaves, etc.

 

 

 

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

 

 

 

3.

Verify that termination cap clearance to subsequent construction (building additions) has been maintained.

 

 

 

 

4.

Inspect for corrosion or separation.

 

 

 

 

5.

Verify weather stripping, sealing and flashing remain intact.

 

 

 

 

6.

Inspect for creosote and remove as needed. (See Sections 10 and 11)

 

 

 

Grate

1.

If grate burns out, it should be replaced only with the grate specified on the rating plate and in the replacement

 

 

parts list for this fireplace.

E. Chimney Fire

In the event of a chimney fire:

Have the chimney and adjacent structure inspected by qualified professionals. Hearth & Home Technologies recommends that NFI or CSIA certified professionals, or technicians under the direction of certified professionals, conduct a minimum of an NFPA 211 Level 2 inspection of the chimney.

Replace components of the chimney and fireplace as specified by the professionals.

Ensure all joints are properly engaged and the chimney is properly secured.

A chimney fire can permanently damage your chimney sys- tem. Failure to replace damaged components and make proper repairs creates risk of fire.

Heat & Glo • RHW-485 • 33221 Rev O • 08/06

35

Page 35
Image 35
Hearth and Home Technologies RHW-485H owner manual Maintenance Task List, Chimney Fire, When cleaning glass door, Clean

RHW-485, RHW-485H specifications

Hearth and Home Technologies (HHT) is a leader in the manufacture of innovative and high-quality hearth products, and their RHW-485H and RHW-485 models are no exceptions. These wood-burning heaters are designed to provide efficient and effective heating solutions for residential spaces while offering an elegant aesthetic that complements various home decors.

One of the main features of the RHW-485H and RHW-485 is their impressive heating capacity. Both models are designed to heat areas up to 2,000 square feet efficiently, making them ideal for large living spaces or open-concept homes. This significant heating capability is made possible by advanced combustion technology that allows for a longer burn time, ensuring extended warmth throughout the night.

Another defining characteristic of these units is their clean-burning technology. HHT has incorporated a unique air wash system that enhances combustion efficiency and minimizes emissions. This ensures that homeowners can enjoy the beauty and comfort of a wood fire while adhering to environmental standards. Furthermore, these models have received certification from the EPA for meeting stringent guidelines, making them an excellent choice for those who are environmentally conscious.

In terms of design, the RHW-485H features an attractive cast iron door with a large viewing window. This allows for an unobstructed view of the mesmerizing flames and adds a touch of sophistication to any room. The RHW-485, while similar in heating efficiency, offers slightly different aesthetic options, giving homeowners the ability to choose a model that aligns with their personal style.

Both models come equipped with a robust refractory system that enhances heat retention and distribution. This technology ensures that heat is released evenly and efficiently, providing consistent warmth without the need for constant refueling. Additionally, they feature adjustable air controls that allow users to manage burn rates and heat output according to their preferences.

Another important aspect is the ease of installation and maintenance. The RHW-485H and RHW-485 have been designed with user-friendly features, including accessible clean-out ports that simplify ash removal. This reduces the hassle of routine care, allowing homeowners to enjoy their fireplace without extensive upkeep.

In conclusion, Hearth and Home Technologies’ RHW-485H and RHW-485 models are premium wood-burning heaters that combine efficiency, elegance, and environmental responsibility. They offer a perfect blend of modern technology and classic design, making them an excellent choice for discerning homeowners looking to enhance their living space with warmth and style.