Image 6

Location of the fireplace and chimney will affect performance.

As shown in Figure 2.1 the chimney should:

Be installed through the warm airspace enclosed by the building envelope. This helps to produce more draft, especially during lighting and die-down of the fire.

Penetrate the highest part of the roof. This minimizes the effects of wind turbulence.

Be located away from trees, adjacent structures, uneven roof lines and other obstructions.

Offsets can restrict draft so their use should be minimized. Consider the fireplace location relative to floor and ceiling and attic joists.

 

Recommended

Recommended

 

Location

 

 

Location

Location

Marginal

 

Location

 

Not

 

 

 

Recommended

 

 

 

 

Location

 

 

Not

 

 

Recommended

Windward

 

 

Outside Air Intake

Leeward

 

Multi-level Roofs

 

Figure 2.1 Recommended Chimney Locations

 